16
Installation
(for qualified installers only)
© Travis Industries
1/3/18 - 1444
Cypress GSR2
Rear Vent Configuration with No Rise
•
Use the minimum vent kit “D” from Travis Industries (SKU 96200317). This kit contains the following
components used to vent the stove through a typical exterior wall:
-- Travis Thimble (unique to this stove)
-- Wall Cover (Black)
-- Pipe Section (3.9”)
-- Pipe Section (6”)
-- Snorkel Cap (14” – unique to this stove)
-- Rear Vent Conversion Parts (cover plates, starter sections, etc.)
•
No elbows (45° or 90°) may be used (no corner installations).
•
Maximum Horizontal Run of 2’ (additional 8” co-axial vent may be used).
•
Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel.
•
Diffuser must be closed (see page 14).
•
Exhaust restrictor must be removed.
•
Do not install the exhaust restrictor extender.
8" Diameter Vent
Max. 2' (610mm) length
Typical 8-1/2" (216mm)
Min. 12" (305mm)
Grade
Travis Thimble
(unique to this stove)
Travis Snorkel
(unique to this stove)