CHAPTER 9 Appendix B: 1 + 1 Protection between TDMoE and QE1/T1 Card
63
NOTE:
To make sure whether the MAP is activated, users can check the Current TSI MAP from the
System Main Menu.
¾
Command Path: AM3440 Controller Menu > (C) System Configuration > (D) Current TSI MAP
L O O P A M 3 4 4 0 - A = = = S y s t e m C o n f i g u r a t i o n ( C u r r e n t M a p ) = = 15:51:10 08/03/2011
A R R O W K E Y S : C U R S O R M O V E , T A B : R O L L O P T I O N S
C u r r e n t M a p
S l o t N u m b e r : 1 T D M o E P O / T S D S L / P O T S P O / T S D S L / P O T S
P o r t N u m b e r : P 1 N O N - C A S = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
1 1 d 2 1 1 1 1 7 d 2 1 1 7
1 2 d 2 1 2 1 1 8 d 2 1 1 8
1 3 d 2 1 3 1 1 9 d 2 1 1 9
1 4 d 2 1 4 1 2 0 d 2 1 2 0
1 5 d 2 1 5 1 2 1 d 2 1 2 1
1 6 d 2 1 6 1 2 2 d 2 1 2 2
1 7 d 2 1 7 1 2 3 d 2 1 2 3
1 8 d 2 1 8 1 2 4 d 2 1 2 4
1 9 d 2 1 9
1 1 0 d 2 1 1 0
1 1 1 d 2 1 1 1
1 1 2 d 2 1 1 2
1 1 3 d 2 1 1 3
1 1 4 d 2 1 1 4
1 1 5 d 2 1 1 5
1 1 6 d 2 1 1 6
< < P r e s s E S C t o r e t u r n t o p r e v i o u s m e n u > >
9.3.4.
Configure Clock Source
After activating the TSI Map, the last step is to setup the clock source.
¾
Command Path: AM3440 Controller Menu > (S) System Setup > (K) Clock Source Setup
For AM3440#1, the Master/Second clock source is
INTERNAL
.
L O O P A M 3 4 4 0 - A = = = S y s t e m S e t u p ( C L O C K - N o r m a l M o d e ) = = = 1 4 : 1 4 : 0 7 0 9 / 0 9 / 2 0 0 8
A R R O W K E Y S : C U R S O R M O V E , T A B : R O L L O P T I O N S
M a s t e r _ C l k S o u r c e : I N T E R N A L C l o c k H o l d - O v e r : O N
S e c o n d _ C l k S o u r c e : I N T E R N A L
C u r r e n t C l o c k : M A S T E R _ C L K
C l k _ R e c o v e r _ M o d e : A U T O M A T I C
C l o c k S t a t u s : N O R M A L
E x t . C l o c k T y p e : E 1 ( 7 5 o h m )
D u a l E x t e r n a l C l o c k P r o t e c t i o n : D i s a b l e
< < P r e s s E S C k e y t o r e t u r n t o p r e v i o u s m e n u > >
NOTE:
For AM3440#2, the clock source is bundle clock. Hence, the Master clock source will be
SLOT_1 P1
, and Second clock source is
SLOT_2 P1
.
After the entire process of setting up 1+1 protection for both AM3440#1 and AM3440#2 are complete,
users can ascertain whether the settings are successfully configured by checking the bundle status. If
the bundle status is active, then the configuration is accomplished.
Summary of Contents for AM3440 series
Page 2: ...2011 Loop Telecommunication International Inc All rights reserved Version 6 5 AUG 2011...
Page 10: ...CHAPTER 1 PRODUCTION DESCRIPTION 4 Point to Multi Point Application Remote Management...
Page 20: ...CHAPTER 5 TERMINAL OPERATION 14 Figure 5 2 VT100 Menu Tree SETUP Section...
Page 21: ...CHAPTER 5 TERMINAL OPERATION 15 Figure 5 3 VT100 Menu Tree DISPLAY Section...