66
the electrical system of loader is energized.
3.
START
--Insert and clockwise turn the starter
switch, the second position is “START”. With the
key at “START” position, the motor is energized to
start the engine. Immediately release the key
after the engine has been started, the key will
automatically return to “ON” position.
Before starting the engine, check that the negative-pole switch of the battery is
turned to “ON” position, and the gearshift handle is at the “Neutral” position.
If the engine cannot be started successfully, turn the starter switch to “OFF”
position, and then start the engine again, and do not just turn the starter switch to
“ON” position and then start the engine again. Failure to do so will cause damage
to the starter switch! Each time of starting shall not take more than 15 seconds;
interval between two times of starting shall be at least 30 seconds; do not
continuously start the engine for more than 3 times; if it is necessary to start the
engine for more than 3 times, wait until the motor cools down. Failure to do so will
shorten the service life of battery and cause damage to the motor.
3.4 SERVICE BRAKE PEDAL
The service brake pedal (foot brake) is arranged
on the left front floor of cab. To apply brake to
front and rear axles, tread the service brake
pedal. In this case, the brake lamp will light up.
When one circuit fails, the other circuit is not
affected so that the machine maintains partial
braking ability, thus ensuring safety. The failed
circuit shall be repaired in time so as to ensure
that the machine has enough braking ability.
To release service brake, take your foot off the
pedal.
Warning
Warning