Longtime LTCU Series User Manual Download Page 2

z

 

This

 

UPS

 

is

 

designed

 

with

 

Off

 

Mode

 

charging,

 

so

 

UPS

 

will

 

charge

 

battery

 

continuously

 

when

 

UPS

 

is

 

under

 

AC

 

normal.

 

If

 

users

 

intend

 

to

 

power

 

off

 

UPS

 

completely,

 

users

 

have

 

to

 

plug

 

out

 

power

 

cord

 

from

 

the

 

Utility.

 

z

 

Press

 

on

 

main

 

switch

 

for

 

4

 

seconds

 

when

 

the

 

Utility

 

is

 

black

 

out,

 

UPS

 

will

 

be

 

turned

 

on

 

and

 

then

 

go

 

to

 

back

 

up

 

mode.

 

To

 

turn

 

off

 

the

 

UPS,

 

please

 

press

 

main

 

switch

 

for

 

4

 

seconds

 

again.

 

If

 

users

 

want

 

to

 

turn

 

on

 

UPS

 

again,

 

please

 

wait

 

for

 

10

 

seconds

 

to

 

press

 

main

 

switch

 

for

 

4

 

seconds

 

again.

 

z

 

When

 

UPS

 

is

 

under

 

battery

 

mode

 

and

 

battery

 

voltage

 

is

 

too

 

high

 

or

 

too

 

low,

 

buzzer

 

will

 

beep.

 

z

 

Buzzer

 

will

 

beep

 

twice

 

every

 

8

 

seconds

 

when

 

the

 

Utility

 

is

 

black

 

out.

 

To

 

silence

 

alarm,

 

please

 

simply

 

press

 

main

 

switch.

 

To

 

restart

 

alarm,

 

please

 

press

 

main

 

switch

 

again.

 

 

6.

 

STORAGE

                                           

 

 

To

 

ensure

 

battery

 

lifetime,

 

please

 

kindly

 

read

 

and

 

also

 

follow

 

below

 

instruction

 

completely.

 

 

The

 

UPS

 

is

 

shipped

 

from

 

the

 

factory

 

with

 

its

 

internal

 

battery

 

fully

 

charged,

 

however,

 

some

 

charge

 

maybe

 

lost

 

during

 

shipping

 

and

 

the

 

battery

 

should

 

be

 

recharged

 

prior

 

to

 

use.

 

Plug

 

the

 

UPS

 

into

 

an

 

appropriate

 

power

 

supply

 

and

 

allow

 

the

 

UPS

 

to

 

charge

 

fully

 

by

 

leaving

 

it

 

plugged

 

in

 

for

 

at

 

least

 

10

 

hours.

 

 

Extend

 

Storage

 

 

Storage

 

Temperature

 

Recharge

 

Frequency

 

Charging

 

Duration

 

15

 ‐ 

30

C

 

Every

 

6

 

months

 

10

 

hours

 

30

 ‐ 

45

C

 

Every

 

months

 

10

 

hours

 

 

7.

 

INDICATION

 

AND

 

CONTROL

                   

 

 

NO.

Indication

 

Description

 

1

 

Alarm

 

mode

 

The

 

audible

 

alarm

 

is

 

enabled.

 

In

 

the

 

back

 

up

 

mode

 

a

 

short

 

touch

 

at

 

the

 

control

 

button

 

will

 

reset

 

the

 

alarm

 

mode

 

2

 

Input

 

&

 

output

 

voltage

 

When

 

UPS

 

is

 

turned

 

on,

 

LCD

 

will

 

show

 

input

 

and

 

output

 

voltage,

 

input

 

voltage

 

will

 

blink

 

continuously

 

in

 

back

 

up

 

mode

 

3

 

Battery

 

capacity

 

Estimated

 

battery

 

capacity,

 

the

 

accuracy

 

is

 

influenced

 

by

 

UPS

 

operation

 

mode

 

and

 

load

 

level

 

4

 

Load

 

level

 

The

 

load

 

level,

 

percentage

 

of

 

load

 

5

 

Frequency

In

 

the

 

normal

 

mode,

 

a

 

short

 

touch

 

at

 

the

 

button

 

will

 

display

 

I/P

 

frequency

 

for

 

10

 

seconds.

 

 

8.

 

TROUBLE

 

SHOOTING

                             

 

Upon

 

UPS

 

failure,

 

please

 

kindly

 

check

 

UPS

 

by

 

following

 

steps.

 

If

 

there

 

is

 

no

 

problem

 

with

 

below

 

points,

 

please

 

kindly

 

send

 

UPS

 

for

 

service.

 

 

z

 

Is

 

main

 

power

 

switch

 

turned

 

on?

 

z

 

Is

 

the

 

UPS

 

plugged

 

into

 

a

 

working

 

wall

 

outlet?

 

z

 

Is

 

the

 

line

 

voltage

 

within

 

the

 

rating

 

specified?

 

z

 

Is

 

the

 

fuse

 

broken

 

(at

 

rear

 

panel)?

 

z

 

Is

 

the

 

UPS

 

overload?

 

z

 

Is

 

the

 

battery

 

not

 

fully

 

charged?

 

 

Please

 

provide

 

the

 

following

 

information

 

when

 

call

 

for

 

service:

 

 

z

 

Model

 

number,

 

serial

 

number

 

z

 

Date

 

of

 

the

 

problem

 

occurred,

 

date

 

of

 

purchase

 

z

 

Full

 

description

 

of

 

the

 

problem

 

including

 

load,

 

LCD

 

and

 

alarm

 

status,

 

installation

 

condition,

 

working

 

environment,

 

etc.

 

 

Problem

 

Possible

 

cause

 

Action

 

to

 

take

 

ON/OFF/silence

 

button

 

not

 

pushed

 

or

 

push

 

time

 

too

 

short

 

Press

 

ON/OFF/sile
nce

 

button

 

more

 

than

 

1

 

second

 

Battery

 

voltage

 

less

 

than

 

10V

 

Recharge

 

the

 

battery

 

PCB

 

failure

 

Replace

 

PCB,

 

call

 

for

 

service

 

UPS

 

can

 

not

 

turn

 

on

 

LCD

 

not

 

light

 

Load

 

less

 

than

 

25W

 

at

 

battery

 

mode

 

Normal

 

condition,

 

no

 

load

 

shutdown

 

function

 

is

 

active

 

 
 

Power

 

cord

 

lose

 

Plug

 

in

 

the

 

power

 

cord

 

AC

 

fuse

 

burn

 

out

 

Replace

 

the

 

AC

 

fuse

 

UPS

 

always

 

at

 

battery

 

mode

 

PCB

 

failure

 

Replace

 

PCB,

 

call

 

for

 

service

 

Battery

 

not

 

fully

 

charged

 

Recharge

 

the

 

UPS

 

at

 

least

 

5

 

hours

 

Back

 

up

 

time

 

to

 

short

 

Battery

 

defective

 

Replace

 

the

 

battery

 

Buzzer

 

continuo
us

 

beeping

 

Overload

 

Remove

 

some

 

loads

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 