background image

 

Installing Network Cables 

 

1. 

Crossover or straight-through cable

: All the ports on the switch 

support Auto-MDI/MDI-X functionality. Both  straight-through or 
crossover cables can be used as the media to connect the switch with 

PCs as well as other devices like switches, hubs or router.   

 
2. 

Category 3,4,5 or 5eUTP/STP cable

: To make a valid connection and 

obtain the optimal performance. An appropriate cable that corresponds 
to different transmitting/receiving speed is required. To choose a 

suitable cable, please refer to the following table. 

 

Media 

Speed 

Wiring 

10Mbps 

Category 3,4,5 UTP/STP 

100Mbps 

Category 5 UTP/STP 

10/100/1000Mbps 

copper 

1000Mbps 

Category 5,5e UTP/STP 

 

 

Network Application 

 

www.DataSheet4U.com

Summary of Contents for LCS-GS8208-A

Page 1: ...Longshine Technologie Europe GmbH LCS GS8208 A 8 Port Gigabit Switch Webmanaged www longshine de www DataSheet4U com...

Page 2: ...t to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE...

Page 3: ...ORK CABLES 9 NETWORK APPLICATION 9 FUNCTIONAL DESCRIPTION 10 JUMBO FRAME 10 FLOW CONTROL AND BACK PRESSURE 10 MIRROR 10 VLAN 10 TRUNK AGGREGATION 10 QUALITY OF SERVICE QO S 10 SNMP 10 MANAGEMENT GUIDE...

Page 4: ...LOGIN LOGOUT PROCEDURES 28 COMMAND HIERARCHY 29 ENTERING COMMANDS 29 COMMAND DESCRIPTION 30 System Commands 30 Console Commands 31 Port Commands 32 VLAN Commands 34 Aggregation Commands 36 QoS Comman...

Page 5: ...n network Port Aggregation enlarges the bandwidth of backbone connection QoS is supported to secure the bandwidth for some bandwidth demanded services including VoIP or videoconference Flow control al...

Page 6: ...l Error packet filtering l Support Jumbo frame 9K bytes l Supports 144K buffer Memory l Support Web based management interface l 100 240Vac 50 60Hz universal input l FCC Class A CE The Front Panel The...

Page 7: ...bps Blinking Green A valid link is established and there is data transmitting receiving 1000M Off No valid link on this port or the Port is connected at 10 100 Mbps Steady Green A valid link is establ...

Page 8: ...in the range from 100 to 240VAC 50 60Hz Please make sure that your outlet standard to be within this range To power on the switch pleaseplug the female end of the power cord firmly into the receptacl...

Page 9: ...nt components 2 Plug the switch with the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation The switch may be standalone or mounted in a rack Rack...

Page 10: ...like switches hubs or router 2 Category 3 4 5 or 5eUTP STP cable To make a valid connection and obtain the optimal performance An appropriate cable that corresponds to different transmitting receivin...

Page 11: ...ackets that transferred by the source port the monitoring port received all the packets and hence is able to monitor the traffic of this specific port VLAN With VLAN supported the network can be segme...

Page 12: ...you should configure the management station with an IP address and subnet mask that compatible to your switch The factory default value of the switch IP 192 168 1 1 Subnet Mask 255 255 255 0 Default...

Page 13: ...e After authentication procedure the SYSTEM Configuration page shows up as the Homepage You may click the hyperlinks on the left side of each page to get access to each management functions www DataSh...

Page 14: ...switch Management VLAN The VLAN ID of one specific VLAN group that is allowed to manage this switch via WEB based management interface Please fill the VLAN id of the VLAN that is authorized to manage...

Page 15: ...ion on this port Mode Select a speed for this port Auto Speed enables auto negotiation Disable stop the port from functioning Flow Control Mark the checkbox to enable the FDX Flow control or unmark to...

Page 16: ...e members of this VLAN group by clicking those marked checkboxes 2 Clear the VLAN id of the VLAN you want to remove in the VLAN Port column Don t type N A Just leave it blank 3 Click the Apply button...

Page 17: ...le if an Egress tagged port receives an untagged frame it will be transmitted as a PVID tagged frame For the detail tagging status please refer to the following table Untagged Tagged Packet Frames In...

Page 18: ...k groups put the ports number into the same Aggregation group There are eight groups to choose Don t forget to click the Apply to save the setting There three aggregation modes for you to setup SMAC S...

Page 19: ...port based QoS allows users to configure certain ports as high or low priority To give priority level for each port 1 Select Port in the Mode column for those ports that are going to perform port bas...

Page 20: ...de column for those ports that are going to perform tag based QoS Click the Apply button 2 Click the Tag priority button The Tag Priority Setting page shows up 3 Select the port that you are going to...

Page 21: ...figuration 1 Select DSCP in the Mode column for those ports that are going to perform DSCP based QoS Click the Apply button 2 Click the DSCP priority button The DSCP Priority Setting page shows up 3 G...

Page 22: ...ws administrators to analyze the traffic of those ports that are monitored Mirror Configuration 1 Select those ports that are going to be monitored by marking the checkboxes in Monitor Port column 2 C...

Page 23: ...o configure the rules for Storm Control which limits the flow of broadcast and multicast To perform storm control 1 Click on each drop list to specify a speed for each frame type 2 Click the Apply but...

Page 24: ...the drop list 2 Specify a trap IP A trap IP is the destination port for sending trap information which is usually the IP address of network administrators 3 Fill in a name in the Community Get column...

Page 25: ...s respectively for auto and manual modes Auto Search 1 Click the Apply button to start 2 The devices being found are listed below 3 Click the IP address hyperlink to get access to the device Manual Ad...

Page 26: ...statistics or click the Refresh button to renew the statistics Detailed Statistics The Detailed Statistics is provided for users to see the detailed transmitting and receiving status of each port Plea...

Page 27: ...uthentication window Please fill in the username and password to continue Factory Default Restore Factory Default To restore the factory default value click the Yes button Note The IP address of the d...

Page 28: ...BASE T Category 3 4 5 UTP STP RJ 45 100BASE TX Category 5 UTP STP RJ 45 1000BASE T Category 5 5e or enhanced UTP STP Network Data Rate 10 100 1000Mbps Auto negotiation Transmission Mode 10 100Mbps Ful...

Page 29: ...Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that 5 The Function arrow and ctrl keys act as Terminal...

Page 30: ...on the context At top level a list of command groups will be shown At group level a list of the command syntaxes will be shown If given after a command the syntax and a description of the command wil...

Page 31: ...stem level System Configuration all System Restore Default keepIP System UserName name System Password password System Systemname systemname System Reboot System Configuration all Syntax System Config...

Page 32: ...Show system name System Reboot Description Reboot the switch Console Commands Commands at Console level Console Configuration Console Timeout timeout Console Prompt prompt string Console Configuration...

Page 33: ...port portlist Port list Default All ports Port Mode portlist mode Description Set or show the speed and duplex mode for the port portlist Port list Default All ports mode Port speed and duplex mode De...

Page 34: ...uding FCS for frames received on the port Tagged frames are allowed to be 4 bytes longer than the maximum frame size Use the reset option to return to default setting portlist Port list default All po...

Page 35: ...ess mode port VLAN ID and accepted frame type for the port and the permanently stored VLAN table portlist Port list default All ports VLAN Add vidlist portlist Description Add VLAN entry and include p...

Page 36: ...t vid none Description Set or show the port VLAN ID Untagged frames received on the port will be classified to this VLAN ID Frames classified to this VLAN ID will be sent untagged on the port portlist...

Page 37: ...rtlist Description Delete link aggregation group portlist Port list Aggregations including any of the ports will be deleted Aggr Lookup portlist Description Lookup and display link aggregation group p...

Page 38: ...fault All ports tag port diffserv Enable tag port or IP differentiated services class of service for the port default Show mode QoS Port portlist class Description Set or show the port class In tag mo...

Page 39: ...uration Description Show the mirror destination port and mirror mode for source ports Mirror Port port Description Set or show the mirror destination port port Mirror destination port default Show mir...

Page 40: ...ipgateway Default IP gateway default 0 0 0 0 vid VLAN ID 1 4095 default 1 IP Web management Description Activate or deactivate the Web management enable disable Enable disable Web management default S...

Page 41: ...ration Storm Control Setup traffic type option Storm Control Configuration Description Show the Storm Control setting Storm Control Setup traffic type option Description Set or show the storm control...

Reviews: