Operation Instruction:
Ⅰ
Camera Controlling:
Press the number button at the bottom part of remote controller to control the camera, each
number stands for one address, the system defaulted address is 1, “0” stands for “10”
.
Ⅱ
Pre-set setup:
1: Press “up, down, left, right” Direction Key on the remote controller steer the camera to the
required position. When satisfied with the camera’s position, Press “set” button for 3 seconds,
till LED shows “SET-”
2. Then press the button of number you want to preset at the top part of remote controller
3. When the LEN flashes, it means the preset finished.
Ⅲ
Calling Preset Point:
Press the preset No. you have set; the camera can steer into the preset position.
Auto Scan:
1. preset the position “A” and “B”.
2. Press the Key “S1","S2","S3"or"S4” to scan automatically from the Position “A” to “B”.
The speed controlled by “S1” is the slowly, the speed controlled by”S4” is the fastest.
3. The key”F2” also can control the scan direction, from Left to Right.
Ⅳ
Deletion of preset:
Press “CLEAR” for 3 seconds, and select the pre-set point for deletion.
Ⅴ
Switches Inside Instruction:
No.1-7:
Address code of cameras, the code No. can be set as: 00-127 (The controller just can
control 10pcs cameras at present.)
No.8:
Baud rate: OFF: 2400; ON: 9600, the defaulted is 2400 (The controller only support
2400)
No.9:
Protocol: ON: protocol-P; OFF: protocol-D, the defaulted is protocol-D (The controller
only support protocol-D)
No.10:
Resistance between RS485 + and RS485
-
: OFF: no resistance; ON: 120ohms.
Among all cameras, which controlled by the same one remote controller, the one (camera)
with the longest cable (16 meters at the most) needs to be switched to “ON”. (Note: when all
cameras controlled by the same one remote controller, only one camera can be switched to”
ON”)