Plasma Cutters www.LWELD.com
www.longevity-inc.com
15
Main Unit Knob/Button/Function:
1.
On/Off Breaker or Switch:
Either breaker or switch located on the back or
front of the unit will control the unit to be turned on or off.
2.
Power Indicator (If applicable):
Shows unit is powered on. Indicator is
present in some models with a green LED bulb. Other models that do not
feature this LED, will have a lighted power switch.
3.
O.C. Over Current Light:
Illuminates when the duty cycle has been
exceeded or the machine has overheated due to improper ventilation.
Discontinue use until lamp goes out. Allow the fan to continue to run. Once
lamp goes out, you may resume using the unit.
4.
Digital Display:
Displays the approximate amount of amperage set to on the
unit.
5.
2.5/5.0/Auto Second Flow Switch:
Post Flow Switch that allows minimal or
maximum air through to cool your torch. Manual 2.5/5.0 selection available
in some units. Other units have automatic regulated POST FLOW.
6.
AMP Adjustment Knob:
Adjusts the amount of amps to desired AMP
setting.
7.
Ground Clamp Din (+):
Location of ground clamp to be plugged in.
8.
Torch Remote Connector:
2 or 7 pin torch connector plugs here to activate
the torch relay once the trigger is pressed on the torch.
9.
Torch Connector Air Outlet:
Connect torch for air to pass through the unit
and generate the arc at the torch tip.