background image

Continuous Drain Features

 

There are two continuous drain features in this mobile air conditioner unit

 

1. The drain at the side of the unit (A) runs through the exhaust hose and offers continuous drainage via a built-in pump. 

When the cap is on the drain at the bottom of the unit (B) and the condensation tank fills to capacity, the drain (A)’s 
pump will automatically turn on and pump the condensation out of the unit. If the exhaust hose is installed more than 

5.9 feet above the ground, drain (A)’s pump will not work and the condensation must be drained from drain (B) 

2. Drain (B) is located at the bottom rear of the unit and offers continuous drainage via gravity. To use drain (B), place a 

shallow pan underneath the drain outlet and remove the rubber cap. In order to avoid spilling water while moving the 
unit from room to room, please drain the condensation via drain (B) before moving the unit. In addition, whenever you 

will not be using the unit for an extended period of time, such as at the end of the season, again use drain (B) to make 
sure the condensation is completely drained from the unit 

 

BT – 1200 PORTABLE AIR CONDITIONER UNIT Operating Instructions

Soft touch control panel

POWER BUTTON:

 Press to turn the unit ‘’ON’’ or ‘’OFF’’. (Note: The compressor requires up to 3 minutes to start from 

either being switched on, or when changing from dehumidify to any air conditioning cycle chosen) 

FUNCTION BUTTON: 

Press this button to select the air conditioning function or dehumidification function 

TIMER BUTTON: 

Programmable timer ON/OFF button 

TIMER-ON FUNTION: The unit can be set to automatically turn the unit on

While the unit is off, press the ‘’TIMER’’ button to set the number of hours (from 1-12 hours), from the current 
time that you would like the unit to turn on 

When the time elapses, the unit will automatically turn on 

If you press the ‘’POWER’’ key before the time elapses, the set time will be cancelled and the unit will turn on 

TIMER-OFF FUNCTION: The unit can be automatically turned off.

While the is on press the ‘’TIMER’’ button to set the number of hours (from 1-12 hours), from the current time that you 
would like the unit to turn off 

When the time elapses, the unit will automatically turn off 

If you press the ‘’POWER’’ key before the time elapses the set time will be cancelled and the unit will turn off 

A/C FAN SPEED:

 Press the speed button to select either, LOW, MEDIUM, HIGH, or AUTO A/C fan speed. When using 

the auto function, the unit will start at maximum speed. As the room temperature changes up or down, the fan speed 

will adjust accordingly. When the room temperature reaches the set temperature, the compressor will shut off, as 
indicated by the blinking air conditioner indicator light on the control panel, and the fan will continue to operate and 

circulate the air. 

SLEEP CONTROL FUNCTION:

 This function is designed to: (a) gradually increase the thermostat temperature, and 

hence the room temperature as you fall asleep, and (b) shut the unit off. To set the ‘’Sleep Comfort’’ mode, first press 
the sleep button. Then set the number of hours from the current time, that you would like the unit to remain on by 

pressing the timer button until the desired hours are indicated on the LED display. The temperature setting may be 
varied in the ‘’Sleep Comfort’’ mode by pressing the ‘’UP’’ or ‘’DOWN’’ buttons. For each press, the temperature will be 

increased or decreased by 1°C. During the course of this cycle, the microprocessor memory will gradually raise the 
preset temperature 2° - 3°C over a two hour period, maintain that temperature for the balance of the time set, and then 

shut the unit off 

L.C.D DISPLAY:

 Indicates the room temperature and the timer and temperature settings. The units LED displays the 

room temperature as son as the power is turned on and after the timer or temperature is set 

ALARM INDICATOR LIGHT:

 This light will illuminate and this unit will shut off when the condensate tank is full and the 

unit cannot drain. The light will remain on and the unit will remain off until the condensation is drained through Drain 
(B). Please refer to the trouble shooting section at the bottom of the instructions 

TEMPERATURE REGULATION BUTTONS (UP & DOWN):

 These buttons raise and lower the thermostat temperature 

setting by 1° each time they are pressed, ranging from 16°C - 32°C 

Reviews: