SECTION 4. DISASSEMBLY AND SERVICE
b.INSPECTION
CHARGE COIL,
IGNITION COIL
Attach one ohmmeter lead to charge coil’s black lead while
touching the other tester to the iron core. Measured resistance
value should be 0
Ω .
Attach one ohmmeter lead to charge coil’s red/white lead
while touching the other tester to the iron core. Measured
resistance value should be 16
±
5
Ω
。
Attach one ohmmeter lead to charge coil’s brown lead while
touching the other tester to the iron core. Measured resistance
value should be 380
±
50
Ω .
If the measured resistance value doesn’t meet the specification, replace the charge coil.
If the charge coil passes inspection but spark still cannot be produced, replace the ignition coil.
- 34 -