Section 4 Disassembly and service
Connecting rod small end ID
Model
Standard
Service limit
G250F(D)S
18.006-18.017 mm
18.07 mm
Connecting rod big end ID
Original size
Standard
Service limit
30. 22~30.233 mm
30.274 mm
Crankshaft pin OD
Standard
Service limit
29.975~29.99 mm
29.915
Connecting rod big end axial clearance
Standard
Service limit
0.25-0.65 mm
1.1 mm
Connecting rod big end oil clearance(Radial)
1) Clean all oil from the crankshaft neck journal
and inside side.
2) Place a piece of plastic gauge on the crankshaft
neck journal, assemble connecting rod, and tighten
the bolts to specified torque.
Bolt torque
:
14 N·m
ATTENTION
14 N.m
4-29