background image

5

 Troubleshooting

Most problems can be solved without professional help.
All other problems should be referred to a Lomac approved repair shop.

SUVERAIN

®

www.lomac.de

POSSIBLE CAUSES
•  The device has been running 

for too long (thermoswitch 

for safety)

• Error in the controls

•  The connected sanitary  

attachments are leaky  

(valve, cistern)

• The check valve is not tight

•  The vent hole in the lid is 

blocked

•  The drain is to high  

or long or too much elbow  

(loss of pressure)

•  The pump floor is blocked

•  The device is not connected

•  The socket is damaged

•  Problem with the motor or 

with the controls

•  The motor is blocked by  

foreign matter

•  Problem with the motor or 

with the controls

REMEDIES
 •  Pull the plug out of the  

socket. Wait a while then 

plug in again.

•  Alternatively, contact an 

approved customer service 

department

•  Check the 

connected disposer

•  Clean or exchange 

the check valve

• Clean the vent hole

• Check the assembly

•  Alternatively contact 

an approved customer  

servicedepartment.

• breakdown service

• Plug in the device.

•  Alternatively contact 

an approved customer  

service department.

•  Remove the foreign matter 

(See section 6)

•  Alternatively contact 

an approved customer  

service department.

6

 Upgrading

WARNING: Motor or electrical part repairs should 

only be carried out by an approved professional. 

Disconnect the device from the mains before the 

procedure.

a.  Removing the macerator from  

the toilet bowl.

  •  Close the corner valve intake and remove most of 

the water from the toilet bowl

  • Disconnect the pressure mains.
  • Disconnect the supply line.
  • Separate the device from the toilet.

b. Foreign matter

Remove through the Toilet intake with the help  
of a screwdriver or steel wire.
Be careful not to pierce the rubber gasket.

WARNING: The blades are very sharp,  

do not insert hands into the device.

7

 Conditions of guarantee

Suverain products have a 2 year guarantee.  
Failure to comply with the conditions for  
assembly and use of the device will result  
in a loss of guarantee.

ERROR
•  The device disconnects 

abnormally

•  The device turns on 

with interruptions

•  The motor runs intermittently 

and the water in the toilet 

boil runs off slowly

•  The motor runs properly but 

does not switch off or runs 

for a long time

• The motor does not start

•  The motor runs with a rattle 

or spins an does not run.

Summary of Contents for Suverain 500-A

Page 1: ...r Rohrschelle befestigen Dann die Ableitung an den Stutzen anschließen und mit einer Rohrschelle befestigen c Elektrischer Anschluß ACHTUNG Die elektrischen Anschlüsse müssen nach der Montage des Gerätes hergestellt werden Die für ein Badezimmer geltenden Bestimmungen für den elektrischen Anschluß einhalten Der elektrische Anschluß muß von einem Fachmann hergestellt werden Den Apparat an eine Stec...

Page 2: ... der Steckdose ziehen Eine Stunde warten und wieder anschließen Andernfalls sich an einen zugelassenen Kundendienst wenden Die angeschlossenen Entsorger kontrollieren Die Rückschlagklappe reinigen oder austauschen Das Lüftungsloch reinigen Den Einbau überprüfen Andernfalls sich an einen zugelassenen Pannendienst wenden Das Gerät anschließen Andernfalls sich an einen zugelassenen Kundendienst wende...

Page 3: ...nd secure with hose clip Then connect the drain to the neck and fix with a pipe clamp c Electrical connection PLEASE NOTE The electrical connections must be made after assembling the device The instructions for electrical connections for bathroom must be observed The electrical connection must be performed by a professional The device is connected to a 10 16 A 2 Pole earth socket The socket should...

Page 4: ...n approved customer service department Remove the foreign matter See section 6 Alternatively contact an approved customer service department 6 Upgrading WARNING Motor or electrical part repairs should only be carried out by an approved professional Disconnect the device from the mains before the procedure a Removing the macerator from the toilet bowl Close the corner valve intake and remove most o...