OM-ST-4G/6G 15
Maintenance
The LoLo steamer is designed for minimum maintenance and no user adjustments
should be necessary. Certain parts may need replacement after prolonged use. If
there is a need for service, only LoLo Authorized Service Agents should perform the
work.
STEAm lEAK-dOOR AdjUSTmENT
If steam or condensate is seen leaking from around the door, take the following steps:
1.
Check the door gasket. Replace it if it is cracked or split.
2.
Inspect the cooking chamber drain to be sure it is not blocked.
3.
Check drain line to ensure it is free-venting, not clogged, kinked or restricted in
any way.
4.
Adjust the door latch pin to allow for changes that might occur as the
gasket ages. To adjust door:
• Loosen the lock nut at the base of the latch pin, then turn the latch pin
1/4 turn clockwise, and tighten the lock nut.
• After adjustment, run the unit to test for steam leakage.
• If there is still leakage, repeat the adjustment.
• Continue adjusting the pin clockwise until the door fits tightly enough to
prevent leakage. The door hinge may also be adjusted.
USE OF ANY REPlACEmENT PARTS OThER
ThAN ThOSE SUPPlIEd bY lOlO COmmERCIAl
FOOdSERvICE EQUIPmENT OR ThEIR
AUThORIZEd dISTRIbUTORS CAN CAUSE INjURY
TO ThE OPERATOR ANd dAmAgE TO ThE
EQUIPmENT ANd wIll vOId All wARRANTIES.
ImPORTANT
SERvICE PERFORmEd bY OThER ThAN FACTORY-
AUThORIZEd PERSONNEl wIll vOId All
wARRANTIES.
NOTE
: The steamer must be disconnected
from the gas supply system during any
pressure testing of that system which
tests pressures in excess of 1/2 PSI (3.45
kPa).
Photo 15-1
Latch pin is threaded to change
depth. Lock nut secures it at that depth.