![Logosol 0458-395-5352 User Manual Download Page 37](http://html1.mh-extra.com/html/logosol/0458-395-5352/0458-395-5352_user-manual_1937970037.webp)
37
FUNCTIONS
PROBLEM/SYMPTOM
CONTROL/SOLUTION
Nothing happens when you press any
of the keys on the control panel.
Open the box and check the cable that connects to
the keypad, unplug and replace the cable. If it still
doesn't work, then it is likely that the keypad is faulty.
The FEED motor is not working.
Move all the motor’s cables to the up/down motor
controller. Activate UP/DOWN and move the control
lever back or forth. If the motor is working, then it
is likely that the motor controller for FEED is faulty.
If the motor is not working, then it is likely that the
motor is malfunctioning.
The FEED motor only runs backwards.
Check that the speed is not at 0. Press the + button
while FEED is activated and the control lever is
pressed forward.
The UP/DOWN motor is not working.
Move all the motor’s cables to the FEED motor
controller. Activate FEED and move the control lever
back or forth. If the motor is working, then it is likely
that the controller for UP/DOWN is faulty. If the
motor is not working, then it is likely that the motor
is malfunctioning.
The sawhead passes below
the bottom position or above
the maximum position.
Restart the Smart Set and recalibrate the sawhead.
100mm between saw blade and log bed.
The solenoid for motor start is only
activated only for a short period
and then released and the band
saw motor goes back to idling again.
Completely loosen the cable between the solenoid
and the motor, press down the enabling switch
button, and then press the start button. Manually
check that the solenoid is fully drawn to the bottom
and is held in place as long as the enabling switch
button is pressed. If the solenoid is functioning
normally without being connected to the engine,
then it is likely that the cable connecting to the
engine throttle is too tightly tensioned. If it still does
not work, check the cables, see separate instruction.
The solenoid for water cooling
does not work.
Check cables, see separate instruction.
The Smart Set loses contact with
the FEED or UP/DOWN motor during
operation and restart is required
to continue.
Low battery voltage. Charge or replace the battery.
If it still does not work satisfactorily, check the cables,
see separate instruction.
The display is black.
Open the cover and check the cable that goes to the
display, is it properly inserted? Unplug and replace
the cable at both ends. Does pin 1 on the display
go to pin 1 on the circuit board? If not, turn one
of the contacts 180 degrees. Still not working?
Then it is likely that the cable or display is faulty.
It is not possible to restart the band saw
motor after the enabling switch button
is released and then pressed again.
In order for the emergency stop circuit to release
completely requires that the control lever is pushed
forward a little and then released completely.
Try starting the band saw motor now.
The STEP function does not work
as intended and the sawhead continues
past the STEP position set.
The engine’s choke must be activated between
each use of step function.
Timeout is shown on the display
Check data cable, see separate instruction
MSG fail is shown on the display
Communication between the control unit and motor
controls is interrupted. May be due to too low voltage
or gap in data cable.
Up to End is shown on the display
The STEP function reaches outside the sawhead’s
motion range
TROUBLESHOOTING SCHEDULE
Summary of Contents for 0458-395-5352
Page 1: ...SMART SET UP DOWN FOR PETROL ENGINE REV 1 USER MANUAL EN SKU 0458 395 5352...
Page 11: ...11 BOX TP 03 03121 03 03043...
Page 18: ...18 1 x M5x16 1 x M5 04 00624 13 A A B B A B...
Page 22: ...22 03 03129 01 00690 03 03130 21 BOX DV...
Page 23: ...23 22 23 24 25 03 02194 04 00223 The below items can be found in the petrol engine saw pack...
Page 25: ...25 6 x M8 5 x M6X10 5 x M6 28 29 BOX TP...
Page 38: ......
Page 39: ......
Page 40: ...Fiskaregatan 2 SE 871 33 H rn sand SWEDEN 46 611 182 85 info logosol com www logosol com...