background image

 

 

                                                                                       

 

Instruction 
SGL/Panther SGL/Maxi/Mini

 

 

 

 

 

D70 
Page 5 

6.5 Type plate, charger 

The charger shall have a plate stating the dc output voltage in Volt and the dc current in Ampere. 
Standard 24V 

– 15A. 

 

7. Electric functions 

7.1 Function test 

 

Lifting/lowering 

 

Forwards/backwards 

 

Emergency stop 

 

Acceleration 

 

Maximum speed 

 

Capability of the brakes 

 

Multiflex-function 

 

7.2 Battery 

 

Check cable eye and poles on the battery for dirt. 

 

Check the level of liquid on the battery (only open batteries). 

 

7.3 Battery box 

 

Check that the battery box and its cover are not damaged. 

 

Empty the battery bag, if it contains battery acid. 

 

7.4 Electric motors 

 

Check that the electric and mechanic conditions are good. 

 

Check the brushes of the wheel motor (only SGL). 

 

Check the brushes of the pump motor. Minimum length: 10mm. 

 

7.5. Electric supply mains 

 

Check that electric parts are clean and free of verdegris. 

 

Check for loose connections. 

 

Check wear and tear on the wires (insulation scrapped off). 

 

7.6 Fuses 

 

Check that specific fuse areas are intact. 

 

Fuse in main current supply for the drive motor. 

 

Fuse in main current supply for the hydraulic motor 

 

Fuse in control circuit. 

 

7.7 Emergency stop and emergency stop button 

Check that the emergency stop functions. Pressing the emergency stop shall break the current 
supply to the main relay - and thereby the connection through the main relay. The control current 
shall also be disconnected. 
The safety switch is fitted on the top of the handle: If the handle touches a solid body (e.g. the 
operator) during operation, the truck has to stop or change direction (drive forwards). 

 