3.3 Cold and humid operating conditions affect the oil!

Oil becomes thicker as it becomes colder. Therefore avoid allowing
the highlifter to stand unused in the cold.In severe cold, water in the hydraulic
system can condense, with breakdown of gaskets and oil as a consequence.
The highlifter will lower more slowly when the oil is cold.The oil is suitable for use
in the temperature range -10 to +50°C. A thinner oil is recommended for
temperatures lower than -10° C, (if necessary, contact your distributor).

3.4 Bleeding the hydraulic system

With a load of 50-100 kg, the forks must be raised and lowered to top and bottom
position 2-3 times.

4.12 Adjustment of the fork height

The fork height can be adjusted as follows 85...93 mm.

The fork height is adjusted by picking out the plug (A)

Adjustment of the fork height (B):

Turning right: the fork height is raised
Turning left: the fork height is lowered

Hereafter the plug is

fastened again (C)

3.6 Cleaning

When cleaning the highlifter, do not direct the jet onto bearings and seals. Other-
wise the grease will be washed out and the life of the equipment shortened.

Summary of Contents for EHL 1004

Page 1: ...EHL 1004 EHL 1004 EHL 1004 EHL 1004 EHL 1004 Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual Maintenance...

Page 2: ...manufacturedinaccordancewithsafety directives Among the subjects dealt with in this Instruction Manual are Proper application Physical limitations of the product Risks with improper use Therefore plea...

Page 3: ...ge 12 V 12 V 12 V Capacity 60Ah 5h 56Ah 5h 50Ah 5h Recommended for Normal use Severe daily use Where maintenance work is not desired Life in cycles at 80 discharge Approx 300 See note 1 Approx 1200 Se...

Page 4: ...rging voltage for the battery type see point 2 1 For connection and operation see the instructions accompanying the charger The manufacturer recommends a charger of 20 amp capacity During charging the...

Page 5: ...current circuit 2 5 Battery indicator The battery indicator shows the battery charge in The most accurate reading can be obtained after the battery has been allowed to remain idle for 5 10 minutes Ye...

Page 6: ...tory set for maximum design load Emergency stop The highlifter has an emergency stop When activating the emergency stop the main current supply is switched off The movement of the forks stops immediat...

Page 7: ...have self lubricating bearings or are treated with molybde num disulphide grease The correct hydraulic oil is ISO VG 32 containing an additive Wynn s Hydraulic Systems Concentrate The proportion of c...

Page 8: ...s lower than 10 C if necessary contact your distributor 3 4 Bleeding the hydraulic system With a load of 50 100 kg the forks must be raised and lowered to top and bottom position 2 3 times 4 12Adjustm...

Page 9: ...y supply Condition of leads and fuses If faults cannot be traced to these sources contact your dealer but BEFOREASKING THE DEALER FORASSISTANCE TRY THE FAULT LOCATION KEY SYMPTOMS AND OBSERVATIONS Pum...

Page 10: ...c system See point 3 1 3 2 See point 2 3 See point 2 6 See point 2 7 See point 2 6 See point 3 4 Contact the distributor Contact the distributor Contact the distributor Contact the distributor If the...