Logitex LX ACDC/M+K 100 A Operating And Installation Manual Download Page 6

  
                                                                                                                                             - 6 -

 

 

OPERATION & ASSEMBLY REGULATIONS FOR WATER HEATERS: 

Type: electric 
Type: combined with a 1 m

2

 heat exchanger 

 

*) This value specifies the maximum output, which the exchanger is able to transfer to the water in 

the heater, while connecting the exchanger to an external source of heat.  For the LX ACDC/M+KW 200 A,B,C 
model  for  when  connecting the  exchanger  to  a  system  of  floor heating  which  utilises heat  from  the  water 
heater. The output therefore depends on the actual amount of heat accumulated in the heater.  

LX ACDC/M+K(W) A,B,C 

water heaters are mainly intended to utilise both electric energy sources. A stable 

source  of  AC  current  from  the  grid  permanently  heats  water  to  a  temperature  that  is  set  using  the  T1 
thermostat.  In  practice, the recommended  temperature  is  45

C.  Upon  reaching  the  pre-set temperature, 

the T1 thermostat switches off the inlet of AC current.  DC current from photovoltaic panels keeps heating 
the water to the preset temperature on thermostat T2. 
If the water temperature drops (water withdrawal) to below 45°C with the sun shining, the water is very 
quickly  and  effectively  heated  by  both  sources  of  current.  In  the  winter  period  (from  1.Nov.-1.Mar.),  we 
recommend setting thermostat T1 to a higher temperature due to weaker sunshine. 

 

WARNING: The thermometer on the water heater measures the temperature of the metal 
water  container,  and  therefore  there  may  be  deviation  from  the  actual  water 
temperature. 

 

Type  

LX 

ACDC/M+K 

100 A,B,C 

LX 

ACDC/M+K 

125 A,B,C 

LX 

ACDC/M+K 

160 A,B,C 

LX 

ACDC/M+K 

200 A,B,C 

LX ACDC/M + KW 

200 A,B,C 

Electrical current for 
heating    

AC+DC 

AC+DC 

AC+DC 

AC+DC 

AC+DC 

Heat losses [kWh/24h] 

0,88 

1,09 

1,39 

1,4 

1,4 

Capacity [l] 

95 

120 

147 

195 

195 

Weight [kg] 

58 

64 

72 

88 

88 

Height x diameter [mm] 

881 x 524 

1046 x 524 

1235 x 524 

1287 x 584 

1287 x 584 

Power input of AC coil 
[kWh] 

Exchanger heat transfer 
surface [m

2

Rated thermal output at 
heating water 
temperature of 80°C and 
flow 720l/h l/h [kW] 

24 

24 

24 

24 

24* 

Table 1 

Summary of Contents for LX ACDC/M+K 100 A

Page 1: ...DC M K 200 A B C LX ACDC M KW 200 A B C MANUFACTURER LOGITEX spol co s r o Ltd portovcov 884 4 SK 02001 P chov Phone no 421 42 4710200 Fax 421 42 4642300 logitex logitex sk Made in Dru stevn z vody Dr...

Page 2: ...C HOT WATER HEATER 10 4 4 DIMENSIONS OF LX ACDC M K 100 A B C LX ACDC M K 125 A B C LX ACDC M K 160 A B C LX ACDC M K 200 A B C 11 5 Operating activity 11 6 Accessories 12 7 Wall mounting 12 8 Plumbi...

Page 3: ...be observed The product s reliability and safety have been verified by tests implemented by EVP Nov Dubnica The manufacturer reserves the right for engineering modification of the product The product...

Page 4: ...ing qualities Voltage 30V 10 and Current 8 3A 5 1 FV panel Photovoltaic panels can be installed at any place with maximum sunshine and south oriented but must not be freely accessible due to the fact...

Page 5: ...ementary system for already existing system of water heating for users using a system in which the heater is placed before or after the system All water heaters of the M K W line are equipped with a t...

Page 6: ...m photovoltaic panels keeps heating the water to the preset temperature on thermostat T2 If the water temperature drops water withdrawal to below 45 C with the sun shining the water is very quickly an...

Page 7: ...n control light signalizes the input of the direct current from the photovoltaic panels If it is on the panels are producing electrical energy Heating water by means of AC current from network is indi...

Page 8: ...hrough its reaction with water it creates an environment that prolongs the lifetime of the tank The design of the anode and the material used comply with the standard EN 12438 A thermometer that trans...

Page 9: ...9 4 TECHNICAL DESCRIPTION 4 1 DIAGRAM OF LX ACDC M K 100 A B C LX ACDC M K 125 A B C LX ACDC M K 160 A B C LX ACDC M K 200 A B C Figure 2 4 2 DIAGRAM OF LX ACDC M KW 200 A B C Figure 3...

Page 10: ...10 4 3 DIMENSIONS OF THE LX ACDC M KW 200 A B C HOT WATER HEATER Figure 4...

Page 11: ...cet hot water valve is opened the water from the water supply conduit pressed out by cold water pressure flows out of the heater Hot water flows out through the top part and water flowing in remains i...

Page 12: ...afety valve with a membrane spring The safety valve must be easily accessible as close to the heater as possible The inlet pipes must have at least the same clearance as the safety valve The safety va...

Page 13: ...afety valve If the pressure in the water piping exceeds 0 6 MPa we recommend installation of a pressure control valve as well The appliance is not designed to be serviced by people including children...

Page 14: ...Connection to electric network shall be executed only after the plumbing has been installed Elements for disconnection from the electric grid must be built into the fixed electric grid distribution t...

Page 15: ...dicator of DC spiral activity TP Heat fuse S3 Indicator of AC spiral activity St1 Contactor for switching on FV heating St2 Contactor for switching between R1 AC Heating element R2 DC Heating element...

Page 16: ...ing system Check proper placement of operating and safety thermostat sensors The sensors in the well must be inserted all the way in first the operating and then the safety thermostat b Open the hot w...

Page 17: ...ting the LX ACDC M KW 200 A B C for floor heating systems for low energy and passive homes Figure 8 Fire fighting regulations for heater installation are defined in relevant standards The heater must...

Page 18: ...rial has been paid for the packaging in which the water heater was delivered The service fee was paid in accordance with Act no 477 2001 Coll as subsequently amended at EKO KOM a s The client number o...

Reviews: