background image

 Product Overview

 Unpacking

Remove all items from the packaging. Retain the packaging. If you dispose of it please do so 

according to local regulations.
The following items are included:
•  Main Unit
•  Water Hose
•  Instruction Manual

 Control Panel

  Water Tank Full

When the water tank is full, the WATER FULL indicator will illuminate and beep. The unit will 

automatically stop. Turn off the unit and remove the water tank. Empty the water and then refit 

the water tank. Turn the unit on again and it will continue operation.

 Operation

1.  Connect to the mains socket.
2.  Press   to turn the unit on or off.
3.  Press the MODE button to select either drying mode or dehumidifying mode.

•  If drying mode is selected, the unit will operate continuously regardless of room 

humidity. Only HIGH fan speed is available for this mode.

•  If dehumidifying mode is selected, press the SET button to select the desired room 

humidity. Both fan speeds are available in this mode.

4.  If you need to set auto off function, press   repeatedly to select the hours.
5.  Select other functions by pressing the relevant button.

 Cleaning & Maintenance

Maintenance of your air filter

The air filter of the unit collects dust contained in the air. The build-up of dust reduces the 

efficiency of the unit. To prevent dust from clogging up the unit, always use it with the air filter 

in place.
Always clean the air filter every 2 weeks. If the unit is used in a dusty atmosphere, clean the air 

filter more often.
•  Remove the filter.
•  Clean the air filter with a vacuum cleaner. lf the air filter is very dirty, you can wash it in warm 

water (never use hot or soapy water). Make sure that the air filter is refitted correctly to the 

unit. Do not bend the filter and ensure it is fitted before operating the unit.

Cleaning the unit

•  Clean the unit by using a damp sponge, and dry it with a clean, soft cloth.
•  Never use alcohol or any product containing solvents.
•  Do not immerse the unit in water.

  Hints & Tips

Issue

Solution

The WATER FULL indicator is 

illuminated.

•  Empty the water tank.
•  Refit the water tank in correct position.

Dehumidifying function does not 

work.

•  Humidity level in the room may be too low.
•  Air filter may be dirty; clean the air filter.
•  Make sure that the air openings are not 

obstructed.

Excessive noise.

•  Ensure the unit is on a stable flat surface.
•  Clean the air filter.

No air coming out.

Clean the air filter.

 Continuous Draining

Water can be automatically emptied into a floor drain by attaching the water hose to the unit.
•  Insert the water hose into the drain outlet. Place or connect the other end of the hose to a 

suitable drainage facility.

•  If items are missing or damaged, please contact Partmaster (UK only).

•  Tel: 0344 800 3456 for assistance.

The unit is equipped with compressor protection. If the unit has been switched 

off and needs to be switched on again immediately, the compressor will delay 3 

minutes to start up.

The hose level must be lower than the drain outlet (as shown below). When the 

hose is not being used, remove the hose from the drain outlet.

Front View

Rear View

Recessed  

Handle

Air Filter

Water Tank

Louvre

Control 

Panel

1  Power 

Press to turn the unit on/off.

2  MODE 

Press to select drying mode (DRY) or dehumidifying mode (DEHUM).

3  LOCK 

Press and hold for 3 seconds to lock/unlock buttons.

4  SET 

Press to select room humidity level: 40% / 50% / 60% / 70% / CO.

5  IONIZER 

Press to turn on/off the negative ion release function.

6  SWING 

 Press to set the louvre to auto-swing or stop swinging.

7  SPEED 

Press to select HIGH or LOW speed.

8  TIMER 

Press to set the auto off function (select from 1/2/4/8 hours).

9  DEFROST  

The indicator will illuminate when the unit enter defrost mode.

10  WATER FULL 

The indicator will illuminate when the water tank is full.

 Before Use

1.  Place on a stable, flat floor. If the floor surface is not even:

•  Vibration and noise will occur.
•  Water may leak from the water tank.

2.  Make sure the air openings are clear and free from blockage.

 Auto-Defrost

When using the appliance in low temperature environments, frost may build up inside the unit. 

The unit has an automatic defrosting function and will automatically activate defrost mode. The 

DEFROST indicator will illuminate.

 Suitable Environments

This unit is designed to operate in the following ambient room conditions:
• Minimum: 5ºC, 40%RH 

• Maximum: 35ºC, 90%RH

It is suitable for use in bedrooms, studies, cellars/basements, kitchens, storage rooms, libraries, 

galleries and computer rooms.
It is also suitable for use to protect moisture-sensitive items, such as most musical instruments, 

cameras and computers.
Benefits:
• Prevents clothes and leather products from becoming mouldy.
• Dehumidifies flooring and carpets.
• Protects ceiling and windows from condensation.

1

2

3

4

5

6

7

8

9

10

To obtain best results, try to avoid opening and closing windows and doors.

Drain Outlet

L20DH16_IB_RC_170116_grace.indd   4-6

16/1/17   11:21 am

Reviews: