7.3  ADJUSTING THE TABLE TO A MEMORY POSITION

Version A (without double-click function):

2

1.  Press and hold the required Memory Position Key (e.g. 2). 

 

▸ The Table Top will move until the saved Table Top height has been reached. If 

you release the Key before the Memory Position is reached, the table will stop.

2

2.  Release the Memory Position Key 

7 3 7 

 

▸ The display shows the Table Top height (e.g. 73 cm)

Version B (Auto-Movement with double-click function):

INFO

The double-click function is available only for Table Systems sold in US markets. 

INFO

If you press any Key while the table moves to a Memory Position, the Table Top will stop 

moving immediately. To continue, you must select the Memory Position again.

CAUTION

Risk of minor or moderate injury through unauthorized modifications

The firmware is delivered with a deactivated double-click function. If you activate this 

function, the grading of the safety functions according to EN ISO 13849-1 PL b, Category 

B, are no longer valid, as the legal requirements in the standard are no longer met.
•  If you activate the function, perform a new risk new assessment to meet the higher 

safety requirements (EN 60335-1). These cannot be met by LOGICDATA Control 
Boxes.

•  LOGICDATA is not liable for injuries or damage caused by activating the double-

click function

2

Double-click the required Memory Position Key (e.g. 2)

 

▸ The table will move to the Memory Position. You do not have to hold the Key

7 3

 

▸ The display shows the Table Top height (e.g. 73 cm)

Summary of Contents for LOGIC OFFICE HSU Series

Page 1: ...MANUAL Document Version 1 0 May 2019 HSU Valid for HSU C FL LD...

Page 2: ...2019 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51 98 103...

Page 3: ...tion of symbols and signal words 7 2 6 Liability 7 2 7 Residual risks 8 2 8 Skilled Persons 8 2 9 Notes for Resellers 9 3 Scope of delivery 9 4 Unpackaging 9 5 Product 10 5 1 Key Product Features 10 5...

Page 4: ...HSU MANUAL PAGE 4 8 1 Software Dependent Functions 17 8 2 Disassembly 17 8 3 Maintenance 17 8 3 1 Cleaning 17 8 3 2 Replacing a Handset 17 8 4 Troubleshooting 18 8 5 Disposal 18...

Page 5: ...in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentation for Height Adjustable Table Systems The license does n...

Page 6: ...rk with HSU Handsets Ensure that national worker protection conditions and national safety and accident prevention regulations are observed during operation of the system 2 3 INTENDED USE The HSU is a...

Page 7: ...NFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations However risk can result from incorrect operati...

Page 8: ...rect voltage may lead to death or seri ous injury through electric shocks Only supply the HSU with safety extra low voltage SELV Read the product s Type Plate for exact voltage specifications WARNING...

Page 9: ...ng Warranty certificates The French inscription may be accompanied with a translation or translations but no inscription in another language may be given greater prominence than that in French INFO Op...

Page 10: ...of the HSU is denoted by the product s order code Consult the accompanying data sheet to ensure that you have received the correct variant 5 1 KEY PRODUCT FEATURES 1 Memory Position Keys 2 Mounting P...

Page 11: ...HSU MANUAL PAGE 11 5 2 DIMENSIONS Length 71 4 mm 5 35 Width 136 0 mm 2 18 Height to underside of Table Top 24 5 mm 0 96 Fig 2 Product dimensions HSU 24 49mm 0 96in 136mm 5 35in m m 4 1 7 n i 1 8 2...

Page 12: ...le handling tools that may cause personal injury Ensure assembly complies with the generally accepted standards and guidelines of electrical engineering and furniture manufacturing Read all instructio...

Page 13: ...3 PROCESS 1 Position the Handset under the table top and mark the position of the Mounting Points 2 Drill the holes for the Mounting Screws into the Table Top at the marked points 3 Use the screwdrive...

Page 14: ...f minor or moderate injury through crushing Failure to release Handset Keys correctly may result in the table failing to stop properly This may lead to minor or moderate injury through crushing Do not...

Page 15: ...ing point has been reached To move the Table Top UP Press and hold the UP Key until the desired height has been reached To move the Table Top DOWN Press and hold the DOWN Key until the desired height...

Page 16: ...ving immediately To continue you must select the Memory Position again CAUTION Risk of minor or moderate injury through unauthorized modifications The firmware is delivered with a deactivated double c...

Page 17: ...CDATA Only use replacement parts produced or approved by LOGICDATA Only allow Skilled Persons to perform repairs or install accessory parts Contact customer services immediately if the system malfunct...

Page 18: ...ol Box 2 Plug the Handset back into the Control Box 3 After a few seconds the Handset is ready for operation A list of common problems and their solutions can be found in the Manual of the installed C...

Page 19: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 5300 Broadmoor Ave SE Suite...

Reviews: