![LOGICDATA DYNAMIC MOTION Configuration Handbook Download Page 21](http://html1.mh-extra.com/html/logicdata/dynamic-motion/dynamic-motion_configuration-handbook_1934838021.webp)
DYNAMIC MOTION SYSTEM - CONFIGURATION HANDBOOK // PAGE 21
6 CHANGING THE TABLE SYSTEM
6.1 REPLACING AN ACTUATOR
1. Disconnect the Power Hub from the Mains
2. Disconnect the Actuator from the Power Hub
3. (If necessary) Disconnect the Acuator Cable using the instructions in Chapter 6.1.1
4. Remove the Height-Adjustable Column from the Table Top
5. Remove the Actuator from the Height-Adjustable Column
6. Mount the new Actuator into the Height-Adjustable Column (see manual)
7. Mount the Height-Adjustable Column back onto the Table Top
8. Plug the Actuator back into the Power Hub
9. Reconnect the system to the Mains
6.1.1 UNPLUGGING THE CABLE FROM THE ACTUATOR
CAUTION
Risk of minor or moderate injury through electric shocks
Inserting foreign objects into connectors may lead to minor or moderate injury
through electric shocks.
• Disconnect the Actuator from the Power Hub before unplugging the Cable.
NOTICE
Unplugging the Actuator Cable incorrectly may damage the connectors irreparably.
• Do not attempt to remove the Actuator Cable by hand
• Consider whether it is necessary to remove the Cable before doing so
1. Disconnect the Power Hub from the Mains
2. Disconnect the Actuator from the Power Hub and wait 10 seconds for residual voltage to dissipate
3. Insert a flat-head screwdriver into the gap behind the cable until it reaches the bottom of the connector
4. Use the screwdriver to lever the Actuator Plug gently upwards and out of the connector
Fig. 7:
Removing the Actuator Cable
6.2 REPLACING A USER INTERFACE
1. Disconnect the Power Hub from the Mains
2. Disconnect the User Interface from the Power Hub
3. Remove the User Interface from the Table Top (use the User Interface's Manual to help you)
4. Mount the new User Interface onto the Table Top (use the User Interface's Manual to help you)
5. Plug the User Interface back into the Power Hub
6. Reconnect the Power Hub to the Mains
6.3 REPLACING A POWER HUB
1. Disconnect the Power Hub from the Mains
2. Disconnect all components from the Power Hub
3. Plug all components into the new Power Hub
4. Reconnect the system to the Mains
Gently lift the Plug
Insert screwdriver
(flat-head recommended)