c a l l t o d a y
0 1 2 1 4 7 2 0 3 6 1
o r e - m a i l
i n f o @ c r a n l e a . c o . u k
Servomex 1440 Oxygen &
Carbon Dioxide analyser
Provides high performance measurement of gases, available in
single modules measuring either Oxygen or Carbon Dioxide or dual
version measuring both.
Also available as a fast response analyser, with a response time of
<200msecs at 150ml/min.
Accuracy
0
2
± 0.1%
C0
2
± 0.1%
Order codes
1440
O
2
/CO
2
analyser - with sample pump
1440 CO2
CO
2
analyser - with sample pump
1440 O2
O
2
analyser - with sample pump
1440SP
Sample pump for 1440 analyser fitted
1440FR
Fast response O
2
/CO
2
analyser with sample pump
Servomex 5200 Multi Purpose analyser
Suitable for measuring levels of Oxygen, Methane, Carbon Dioxide
and Carbon Monoxide. It has a range of sampling and power
options to suit individual needs.
Available with a choice of two paramagnetic oxygen
transducers (standard and high accuracy). They both offer
fast, selective measurement of Oxygen, without the disadvantage
of electro-chemical or zirconia cells.
Accuracy
0
2
± 0.1%
CO
2
± 0.1%
Order codes
5200S
O
2
/CO
2
analyser - standard
5200HA
O
2
/CO
2
analyser - high accuracy
5200/02
O
2
analyser - standard
5200HA/02
O
2
analyser - high accuracy
5200/C02
CO
2
analyser - standard
Factory fitted options
5200 BAT
Rechargeable internal battery
5200 OUT
4 - 20 mA output per channel
Woodway iMETT
Now everyone can experience the benefits of VO
2
testing.
The iMETT from Woodway is an easy to use, inexpensive
metabolic testing system that evaluates and monitors aerobic
fitness by determining each individual’s anaerobic threshold.
Create individualised weight loss or aerobic fitness programmes and
incorporate the iMETT assessment into existing training packages.
Each iMETT program includes
• VE analyser with software to determine cardio programmes
• Design testing protocols
• Additional fitness assessments
Other fitness evaluations are based on predictions, estimates
and outdated charts. We’re all familiar with 220 minus age –
but these programmes have large margins of error and a history
of unreliable results.
Determine a true heart rate training zone with a precise submax
VO
2
test. From the data you’ll be able to provide customised
exercise prescriptions that can help athletes reach their exercise
goals quickly and safely.
Order code
iMETT
5
6
metabolic measurement
63
5
6
7
7
SERVOMEX
WOODWAY
Summary of Contents for Corival
Page 1: ...product range g e t t h e m e a s u r e...
Page 94: ...90 Notes...