78
4 Operator Menu Programming
4.2 Service
Menu
Flow
Chart
• Push * button twice: Access
service menu
, Display:
Enter password
• Use OK button to navigate from menu to menu
• Push ESC key to leave the service menu
115
OK
*
OK
OK
OK
OK
OK
ESC
ESC
ESC
ESC
ESC
OK
Automatic
Flushing Interval
OK/ESC
after 10 min.
Flushing Time
1.0 sec.
OK/ESC
Calibration
100.0 %
OK/ESC
*
Language
english
OK/ESC
PASSWORD
0000
ESC
OK
Suck
Back
Time
0.3 sec.
OK/ESC
ESC
ESC
OK
Cont.
A:B
2.00:1
Max.
70%
OK
Time
9.2
sec.
A:B
2.00:1
Max.
70%
OK
OK/ESC
A
:
B
1.00:1
100%
*