Page 2
1. Please Observe the Following
1.1
Emphasized Sections
Warning!
Refers to safety regulations and required safety measures that protect the operator or
other persons from injury or danger to life.
Caution!
Emphasizes what must be done or avoided so that the unit or other property is not
damaged.
Notice:
Gives recommendations for better handling of the unit during operation or adjustment
as well as for service activities.
1.2 Safety
Do not touch the nozzle or molten adhesive with bare skin as they are hot - the
operating temperature of the Loctite
®
Hysol
®
175-SPRAY and 175-SPRAY-HT
applicators is approximately 400ºF (200ºC). Protective gloves should always be
worn. Careless handling can cause skin burns.
If molten adhesive comes into
contact with the skin immerse the affected area immediately in plenty of cold water.
Seek medical advice if necessary.
In addition to the safety instructions herein, any statutory regulations, local fire
insurance regulations, or other generally valid “regulations for accident prevention”
must be complied with when using this tool.
•
Never use the tool if it is damaged in any way.
•
Do not use this tool in damp rooms, outdoors while it is raining, or where there is
high humidity.
•
Do not use this tool in the vicinity of any heat-sensitive materials, or any flammable
materials, liquids, or gases.
•
Only use extension cables that meet the specification shown in “Technical data”.
•
Never pull on the tool’s connecting cable.
1.3 Items supplied
Loctite
®
Hysol
®
175-SPRAY
•
Pneumatically-driven Hot Melt Cartridge Dispenser, fitted with 356°F (180°C)
thermostat (suitable for standard spray hot melt adhesives)
•
Valve body airline adapter
•
Plastic
Stand
•
Manual
Loctite
®
Hysol
®
175-SPRAY-HT
•
Pneumatically-driven Hot Melt Cartridge Dispenser, fitted with 383°F (195°C)
thermostat (suitable for polyamide spray hot melt adhesives)
•
Valve body airline adapter
•
Plastic
Stand
•
Manual
Summary of Contents for Hysol 175-SPRAY