background image

 

38

 

Appendix

Dimension 

 
CL10 Quad LED Controller  

Power

SET

MODE

ESC

START

STOP

CL10 Quad LED Controller

AC 100~240V  50/60Hz  MAX 0.6A

FUSE: 3 AMP 240VAC

RS232

CH1

CH2

CH3

CH4

SERVICE

CH1

CH2

CH3

CH4

Item No. 1514634
Input: 100~240VAC, 50/60 Hz
Rated Power: 30 W

Henkel China Company Limited
No.928 Zhangeheng Rd. Pudong.
Shanghai. P.R.China 201203
Made In China

Serial No.

 

LED Head 
 
 
 
 
 
 
 
 
 
 

 

 

F6
m

m

1538499

UV

-L

E

D

DA

NGER

L

E

D

 R

A

D

IAT

IO

N

AVO

ID

 EXPO

SU

R

E

 T

O

 BEA

M

CL

A

S

S

 3

B

 L

E

D P

R

O

D

UCT

UV-LED

DANG

ER

LE

D RA

D

IA

T

IO

N

AVO

ID

 EXPO

SU

R

E

 T

O

 B

EAM

C

L

ASS 3

B

 L

E

D

 PR

O

DUCT

DO NOT INSERT OR REMOVE FROM THE

LENS END

Summary of Contents for 1514634

Page 1: ...EQUIPMENT Operation Manual Loctite CL10 Quad LED Controller Part Number 1514634 ...

Page 2: ...3 PARAMETER CURSOR STATUS 16 5 2 4 INFORMATION ON LCD DISPLAY 16 5 3 OPERATION 17 5 3 1 STARTUP 17 5 3 2 STARTING CONTROLLER 18 5 3 3 WORKING MODE 19 5 3 4 EXIT WORKING MODE 19 5 3 5 STANDBY MODE SETTING 20 5 3 6 PASSWORD SETTING IN PARAMETER PANEL 20 5 4 PARAMETER SETTING 22 5 4 1 ENTER PARAMETER PANEL 22 5 4 2 WORKING MODE SETUP 23 5 5 WORKING MODE DESCRIPTION 25 5 5 1 C C MODE 25 5 5 2 PWM MODE...

Page 3: ...3 5 10 LANGUAGE SETTING 32 5 11 LED HEAD UNIT AND FOOT SWITCH 33 5 12 SHUTDOWN 34 6 TROUBLESHOOTING 35 7 REPLACEMENT PARTS 37 8 APPENDIX DIMENSION 38 9 APPENDIX PLC I O 39 10 WARRANTY 40 ...

Page 4: ...the equipment is handled incorrectly Forbidden This symbol means that the instruction describes prohibited item or actions ELECTRICAL EQUIPMENT This symbol means there is possible serious injury by high voltage Heating This symbol means there is possible serious injury do to high temperatures Info Ultraviolet radiation warning This symbol means that possible serious injury due to Ultraviolet radia...

Page 5: ...he power supply after finishing working Please hold power plug when pulling out the power cable Don t hold the cable it is possible to be injured by electrical shock Do not allow liquid to enter the equipment Disconnect the power supply before cleaning the equipment Do not use an organic solvent to clean the cabinet In the case of an abnormal condition stop using the equipment immediately 1 2 Out ...

Page 6: ...working hours 2 Thermal radiation free low temperature change on irradiated surface resolves heat damage issues 3 Uniform distribution of irradiating 4 PB free 5 Low energy consumption as compared with mercury lamp systems up to 90 energy savings 6 Small and easy to carry and install 7 Low maintenance cost There are 5 production modes integrated in this equipment C C mode OPT mode PWM mode step mo...

Page 7: ...P 10 steps each step can define intensity and time independently MODE PWM Intensity 0 100 Time Max 999 9 seconds Power Supply AC100 220V 50 60Hz MAX 1 5A Power consumption 30W Cooling method Natural air cooling Temperature range Operating 5 35 Storage 15 65 Humidity Range 20 85 Cabinet Material aluminum Quantity 2Kg Wavelength 365nm 405nm ...

Page 8: ...wer SET MODE ESC START STOP CL10 Quad LED Controller Minimum space required for the equipment Please check the unit for any mechanical defects If there is any breakage due to delivery please stop using equipment and return to supplier ...

Page 9: ...troller AC 100 240V 50 60Hz MAX 0 6A FUSE 3 AMP 240VAC RS232 CH1 CH2 CH3 CH4 SERVICE CH1 CH2 CH3 CH4 Item No 1514634 Input 100 240VAC 50 60 Hz Rated Power 30 W Henkel China Company Limited No 928 Zhangeheng Rd Pudong Shanghai P R China 201203 Made In China Serial No ...

Page 10: ...age machinery Make sure nothing can be placed on power cable and that it will not be reachable by the operator Keep away from heating sources Avoid places with high temperatures or extreme cold Allow for adequate ventilation so that exhaust from the heat outlet does not remain around the equipment Info Where there are ventilation holes please do not block Make sure unit is well ventilated ...

Page 11: ...nect power cable to the controller as pictured below 3 There are 4 LED head connectors on the back side of the controller named CH1 CH2 CH3 CH4 Connect LED heads one at a time Align the groove on the main unit and red point on the LED head unit with the cable plug ...

Page 12: ...ing the adapter to the controller be sure to align the numbers as shown above Be sure to insert the connector fully After finishing symbol CH1 CH2 CH3 CH4 should in up direction To operate CH s switch press one time to turn on the LED head press again to turn off Output signal follows PLC standard level 0V means LED head is working ...

Page 13: ...13 5 Connect PLC Option PLC Note To operate CH s switch press one time to turn on the LED head press again to turn off Output signal follow PLC standard level 0 24V 0V means LED head is working ...

Page 14: ...o 928 Zhangeheng Rd Pudong Shanghai P R China 201203 Made In China Serial No 8 8 7 1 2 4 3 6 5 10 9 1 LCD display All settings data and information will be shown here 2 Arrow Key Move cursor up down or left right 3 SET Button Confirm or enter menu 4 Power Switch Power On Off 5 Mode ESC Back or exit menu 6 Start Stop Enter or exit pre irradiance mode Note Pre irradiating mode When controller is in ...

Page 15: ... 10 Service port 5 2 Button and operating panel instructions 5 2 1 Controller button instruction Mode ESC Back or exit menu without change Power Start Stop Enter or exit pre irradiance mode SET Button Confirm or enter menu Arrow Keys Move cursor up down or left right Power Switch Power On Off ...

Page 16: ...dark means it cannot be changed changeable Cursor in half dark means it can change mode and parameters through the arrow keys 5 2 4 Information on LCD display Pre irradiance mode In Pre irradiance mode LED head unit on off is controlled by the foot switch or PLC signal Parameter setting information Parameter change successful Language setting information Language change successful STEP Parameter L...

Page 17: ... Warning Please place this equipment in a stable space Avoid a place with high voltage machinery Please do not block its ventilation holes Don t expose to flammable gas Don t use in high temperatures or extreme cold To avoid electric shock don t use the equipment when servicing Caution To avoid button damage please don t press the button with high pressure Please avoid metallic foreign matter from...

Page 18: ... installation plug in power cable then press When the red LED light inside of turns on the LCD will show processing as follows Power Power To avoid incorrect operation all buttons will be forbidden except Start Stop button in Pre irradiance mode ...

Page 19: ...ssing or will enter working mode Working will show on display At that time you can control LED head by using a foot switch or PLC 5 3 4 Exit Working Mode Press then press to confirm Equipment will stop running Foot switch and PLC controlling will be disabled R S ...

Page 20: ...password Enter Parameter Panel Move cursor here Choose Enable and Disable by pressing the Up Down arrow key Move cursor to Change 0 9 by Up Down arrow key Change target by Left Right arrow key Press to confirm Note Enable Controller will enter Pre irradiance mode automatically during startup Disable Controller can enter standby mode by operating manually ...

Page 21: ...d will reset back to default Default password 1234 Move cursor to After keying in password press to change the password Change 0 9 by Up Down arrow key Change target by Left Right arrow key Press to confirm after keying in new password After two times keying in press the password is changed ...

Page 22: ...22 5 4 Parameter Setting 5 4 1 Enter Parameter Panel 1 Move cursor to 2 Press to enter Menu move cursor to 3 Press to enter parameter panel Parameter SET ...

Page 23: ...r to the cell that is under Mode Chan Mode CH1 PWM CH2 C C CH3 OPT CH4 STEP Press to change cursor goes to half dark Chan Mode CH1 PWM CH2 C C CH3 OPT CH4 STEP Change mode type using arrow key Chan Mode CH1 MAN CH2 C C CH3 OPT CH4 STEP PWM ...

Page 24: ...24 Press to confirm Chan Mode CH1 MAN CH2 C C CH3 OPT CH4 STEP Move cursor to then press to confirm change and save data Repeat the flow if needed to change other data in parameter panel ...

Page 25: ...shed There are 10 steps in one action time and power will follow each step s setting in step panel For detail please check chapter STEP MODE 5 5 4 OPT Mode Use the OPT Optical mode for lens bonding We suggest time settings between 0 1 0 2s Single click foot switch head works as long as the set time During that time it is easy to adjust the lens position and also can be sure that the adhesive will ...

Page 26: ...eys to change unit ten and hundred Finish editing press to confirm cell status goes to unchangeable 100 Move cursor to and press to save Use arrow key to move cursor to the target and edit data as flow Note If set data 100 after confirm the data will change to 100 automatically If the data set to 0 and confirm save related head s output goes to 0 means no output ...

Page 27: ...Press up down arrow key to edit data 1 4 Select related foot switch press to confirm Data go to unchangeable 1 Move cursor to and press to save Use arrow key to move cursor to the target and edit data as flow Note Data in Sw column relates to CH1 CH2 CH3 and CH4 on adapter 1 CH1 2 CH2 3 CH3 4 CH4 ...

Page 28: ...y to change units ten and hundred Select related foot switch press to confirm Data goes to unchangeable 010 0s Move cursor to and press to save Use arrow key to move cursor to the target and edit data as flow Note If set time 0 0s will change to 0 1s automatically after confirm and save In manual mode time setting is not working Time range 0 1s 999 9s ...

Page 29: ... There are 10 steps in one action time and power will follow each step s setting in step panel Setting flow Note 1 10 Means from step 1 to step 10 Time working time for each step Intensity Intensity for each step Enter Menu panel Move cursor to Press to step panel as following picture ...

Page 30: ...angeable 002 0s Edit data by up down arrow keys press left right arrow keys to change unit ten and hundred Select related foot switch press to confirm Data go to unchangeable 002 0s Move cursor to and press to save Note If set time 0 0s will change to 0 1s automatically after confirm and save ...

Page 31: ... press left right arrow keys to change unit ten and hundred Select related foot switch press to confirm Data goes to unchangeable 010 Move cursor to and press to save Note If set data is 100 after confirm the data will change to 100 automatically If the data set to 0 and confirm save related head s output goes to 0 means no output ...

Page 32: ...32 5 10 Language Setting Move cursor to the language type that you want to select Press to confirm Press to go back to Menu Enter Menu Move cursor to Press to language panel ...

Page 33: ... Please measure and define working distance properly before using LED head Don t touch the head in use it may cause injury by high temperature Working panel will be shown during running Click foot switch LED head will work as set parameter ...

Page 34: ...START STOP CL10 Quad LED Controller Press power button to turn off controller red indicator will turn off at the same time Note The equipment can run following timer setting Intensity of LED head output can be adjusted adjust range 0 100 ...

Page 35: ...r cable properly 1 Display not on when turning on power button Please check the fuse Fuse type 3AMP 240VAC Please check if LED head is in working status Exit working status enter preparation 2 Cannot set parameter Please check if the controller is locked Key in password unlock controller Step 2 Disconnect power cable ...

Page 36: ... check alignment of the groove on the main unit and red point on the LED head Please check item 3 chapter 4 4 6 Time that is shown on LCD has gone to 0 but the LED head is still working Please check if controller is in manual mode Set to C C mode 7 LED head cannot reach setting intensity when working Please check the working distance Set the working distance properly Please check if LED head is wr...

Page 37: ...e 1538499 CL10 405nm 6mm LED Head 2 7M Cable 1746633 Spare Parts Lens CL10 365nm 6mm LED Lens 1538496 CL10 405nm 6mm LED Lens 1750074 Foot Switch Foot Switch Assembly 97201 Radiometer Visible Light 365nm Radiometer Dosimeter 1390323 Radiometer Ultraviolet Light 405nm Radiometer Dosimeter 1265282 CL10 Radiometer Tip Locator 1403402 ...

Page 38: ...CH2 CH3 CH4 Item No 1514634 Input 100 240VAC 50 60 Hz Rated Power 30 W Henkel China Company Limited No 928 Zhangeheng Rd Pudong Shanghai P R China 201203 Made In China Serial No LED Head F 6mm 1538499 UV LED DANGER LED RADIATION AVOID EXPOSURE TO BEAM CLASS 3B LED PRODUCT UV LED DANGER LED RADIATION AVOID EXPOSURE TO BEAM CLASS 3B LED PRODUCT DO NOT INSERT OR REMOVE FROM THE LENS END ...

Page 39: ...al follow PLC standard level 0 24V 0V effective Note Q1 adapter is only for using foot switch to control Please use PLC connector below when trying to connect a PLC and want to use PLC to control the controller PLC connector is not included in package Manufacturer Phoenix Contact Model No MC 1 5 8 ST 3 81 Article Number 1803633 ...

Page 40: ...nsported handled installed connected operated used or maintained In the event of unauthorized modification of the Products including where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason withou...

Page 41: ...alzada de la Viga s n Fracc Los Laureles Loc Tulpetlac C P 55090 Ecatepac de Morelos MEXICO Henkel Singapore Pte Ltd 401 Commonwealth Drive 03 01 02 Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo ch...