Although the scale is designed to be extremely durable,
it’s important that you never overload or drop/shock the
scale. Scales are delicate instruments and unlike
cellular phones, scales have delicate sensors that
determine how much an item weighs. If you drop or
shock your scale, these sensors “feel” the shock and
are sometimes destroyed; this happens with all digital
scales. Our scales are designed to be resistant to
shock or drops as much as possible, however this no
way to protect 100% against load cell or sensor
damage. A well treated scale will provide years of
reliable and accurate weighing. However an abused
scale will only work until its sensor’s are damaged.
KEY PAD FUNCTIONS
* UNIT
For unit mode selection, press and release the key
once to change weight unit. You can select g (grams),
oz (ounces), dwt (pennyweight), ozt (troy ounces), ct
(carats), gn (grain) or mg.
* PCS (Count) Sample sizes can be 10, 20, 50 or 100
The following steps outline the procedure for cumulative
weighing of samples. Switch the scale On. Place a
given number of samples of an item on the tray. Press
the [UNIT] key several times to put the scale in PCS
mode (noted by PCS indicator on display). Select the
sample size (the same as you chose above) by
pressing the [PCS] key as many times as necessary to
put in the correct sample size. Press the [UNIT] key, the
display will show “pass”, then after 2 seconds, the scale
will remember the sample size you selected and show
the starting sample size on the display (you can now
remove the samples if you want to return to 0 pcs).
Place the items that you want counted onto the tray, the
total number of items will show on the display. Press
the [UNIT] key to exit the counting function and return
to normal weighing.
*
ON/OFF
Press this key to turn unit on. Once the unit is on, press
and hold the same key to turn the scale off.
* ZERO (tare)
Press Zero to reset the scale to zero. This can be used
for eliminating from a sample (or a tray/container) the
weight value of a container weight is permanently
removed for the remainder of the procedure. Just turn
the scale On, place the tray or container on the
weighing platform, and press the Zero key. The scale
will show 0.0 (or 0.000) on the display, and you can add
items to the container/tray.
NOTE: When all weight is removed from the weighing
tray, the tarred value of a container will be displayed as
a negative number, Cycle the power on the scale to
reset the scale.
* LIGHT
Press the [LIGHT] key to turn on the backlight; press
the [LIGHT] key again and the backlight will turn off.
** These electronic scales are precision instruments.
Avoid disturbing environmental conditions such as
currents, vibrations, strong electrical and magnetic
fields as well as rapid change of the ambient
temperature.
* Selection of auto shut off mode
Press and hold [ZERO], then press [ON/OFF]. The
scale will enter the function settings mode. The display
will show A-ON or A_OFF. Press [ZERO], the display
will show A_ON, this means auto shut off function is
active. Press [ZERO] again, the display will show
A_OFF, this means that the auto shut off function is
inactive.
Manual P/N 8901688 Rev B 04/2009
WARRANTY
Henkel expressly warrants that all products referred to in the
Instruction Manual for
1174337
Henkel Micro-Dispense
Scale (hereafter called “Products”) shall be free from defects
in materials and workmanship. Liability for Henkel shall be
limited, as its option, to replacing those Products which are
shown to be defective in either materials or workmanship or
to credit the purchaser the amount of the purchase price
thereof (plus freight and insurance charges paid therefor by
the user). The purchaser’s sole and exclusive remedy for
breach of warranty shall be such replacement or credit.
A claim of defect in materials or workmanship in any
Products shall be allowed only when it is submitted in
writing within one month after discovery of the defect or
after the time the defect should reasonably have been
discovered and in any event, within (12) months after the
delivery of the Products to the purchaser. This warranty does
not apply to perishable items, such as (batteries, tray, cover,
lights, etc.). No such claim shall be allowed in respect of
products which have been neglected or improperly stored,
transported, handled, installed, connected, operated, used or
maintained. In the event of unauthorized modification of the
Products including, where products, parts or attachments for
use in connection with the Products are available from
Henkel, the use of products, parts or attachments which are
not manufactured by Henkel, no claim shall be allowed.
No Products shall be returned to Henkel for any reason
without prior written approval from Henkel. Products shall
be returned freight prepaid, in accordance with instructions
from Henkel.
NO WARRANTY IS EXTENDED TO ANY EQUIPMENT
WHICH HAS BEEN ALTERED, MISUSED,
NEGLECTED, OR DAMAGED BY ACCIDENT.
EXCEPT FOR THE EXPRESS WARRANTY
CONTAINED IN THIS SECTION, HENKEL MAKES NO
WARRANTY OF ANY KIND WHATSOEVER, EXPRESS
OR IMPLIED, WITH RESPECT TO THE PRODUCTS.
ALL WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, AND OTHER
WARRANTIES OF WHATEVER KIND (INCLUDING
AGAINST PATENT OR TRADEMARK
INFRINGEMENT) ARE HEREBY DISCLAIMED BY
HENKEL AND WAIVED BY THE PURCHASER.
THIS SECTION SETS FORTH EXCLUSIVELY ALL OF
LIABILITY FOR HENKEL TO THE PURCHASER IN
CONTRACT, IN TORT OR OTHERWISE IN THE EVENT
OF DEFECTIVE PRODUCTS.
WITHOUT LIMITATION OF THE FOREGOING, TO THE
FULLEST EXTENT POSSIBLE UNDER APPLICABLE
LAWS, HENKEL EXPRESSLY DISCLAIMS ANY
LIABILITY WHATSOEVER FOR ANY DAMAGES
INCURRED DIRECTLY OR INDIRECTLY IN
CONNECTION WITH THE SALE OR USE OF, OR
OTHERWISE IN CONNECTION WITH, THE
PRODUCTS, INCLUDING, WITHOUT LIMITATION,
LOSS OF PROFITS AND SPECIAL, INDIRECT OR
CONSEQUENTIAL DAMAGES, WHETHER CAUSED
BY NEGLIGENCE FROM HENKEL OR OTHERWISE.