Solenoid Wiring
Solenoid Return (0V)
Red
Black
Solenoid Power
(10-30V DC)
100-300mA
Common
N.O. (Normally Open)
Yellow
Violet
Brown
N.C. (Normally Closed)
Latch Monitor Wiring
Door Opened
Solenoid Monitor Wiring:
Unpowered
Common
N.C. (Normally Closed)
Grey
Orange
White
N.O. (Normally Open)
ELECTRICAL SPECIFICATION
Door mounting bracket
Refit strike and secure, making sure no wires are being crushed.
Check both mechanical and electronic operation works correctly.
CHECKING FUNCTION
6
TUBULAR LATCH OPERATION
To ensure deadlatching, ensure
that the deadlatching pin is
depressed by the edge of the
keeper when the door is closed.
Deadlatching
pin.
Keeper
edge.
CAUTION! Incorrect supply voltage may cause damage not covered by warranty.
Please check supply voltage with a suitable meter to ensure it is within 10-30V DC.
Current required is 250mA @12V DC to 130mA @ 24V DC
DO NOT OIL OR LUBRICATE.
9000 Series Microswitch Monitoring
The 9000 Series Electric Strike has back EMF protection built into the product.
No external protection diode is required.
The wiring diagram for the monitoring schematic is shown in Fig. 4 and on the
back of the strike.
5 Year Limited Warranty
ASSA ABLOY Australia guarantees for a period of 5 years in accordance with Trimec’s
Standard Warranty Conditions, against defects in manufacture, workmanship or materials,
provided that all electrical and mechanical installation requirements are adhered to as per
this datasheet. All third party and consequential claims are expressly excluded from
the warranty.
2
5mm Extension lip
50mm Extension lip
75mm Extension lip
P/No. 220200-505
The installation of a Strike guard is recommended on outward opening
external doors.
P/No. 220200-506
P/No. 220200-507
warranty
4 Hr
FIRE RATED
ASSEMBLING STRIKE
5
For metal door frames fit door mounting brackets.
Once door frame preparation is complete, temporarily fit strike into
door frame to check for interference. Check that the door closes
smoothly and that the latch extends fully past the strike keeper.
When strike operates correctly with latch, remove strike from
mortice and connect wiring.
Ensure wires come out
of back as shown