Voltage Adjusting Jump
(Default value as 12V)
12V
24V
Inspection Before Installation
1.Please make sure there is enough space to mount the electromagnetic door holder when.
the door leaf is open wide.
2.Please make sure holding force of door closer is lower than the electromagnetic door holder
(an ordinary door closer's holding force is about 20 kg).
Minimum power supply
220mA@DC12V
220mA
DC12V
Holding force of door closer shall be
lower than electromagnetic door holder's.
Max 65kg
Installations
Step1:Please make sure its mounting position.
P2
Space needed to mount
on the wall.
65mm
Install according to its embedded box's position.
The armature is adjustable Please check
its position before mounting.
Wall
Door le
af
The adjustable angle of the armature
is 75 ( both left and right).
Max 75
Control board