ENGLISH
21
Turnitec (electro)mechanical control module
17. ELECTRICAL WIRING
• Connect the control unit(s) according to electrical scheme
• Electrical control scheme
6 5
1
2
3
4
NO
NO
NC
NC
C
C
21 22 23 24 25 26 27 28 29
20
1
2
3
5 4
6
10 11 12
10L 11L
15
7 8 9
18
10 11 12
15
7 8 9
12L
12R
11R
10R
1 2 3 4 5 6 7
PE
N
L1
N
PE
L1
N
L1
PE
18
CCW
Fail Open
module
Fail Close
module
U max = 250V AC/30V DC
Imax = 2A (resistive)/1A (inductive)
CW
lights
Fail Open
module
Fail Close
module
U max = 250V AC/30V DC
Imax = 2A (resistive)/1A (inductive)
110V/230V AC*
50/60Hz
110V/230V AC*
50/60Hz
110V/230V AC*
50/60Hz
Connection to counter-module.
Connect to “L” for CW-module.
Connect to “R” for CCW-module.
CCW
lights
CW
counter
(0.5s)
Connection to counter-module.
Connect to “L” for CW-module.
Connect to “R” for CCW-module.
Trigger with external NO dry contact relay.
DO NOT APPLY VOLTAGE HERE
Min. requirements:
U: 30V DC
I: 0,2A
Min. impulse length: 30 ms
Max. impulse length: 1s
Trigger with external NO dry
contact relay.
DO NOT APPLY VOLTAGE HERE
Min. requirements:
U: 30V DC
I: 0.2A
Min. impulse length: 30 ms
Max. impulse length: 1s
*110V units are provided for the US market