background image

 
 
 

 

PUMP-Rec-05 

PUMP 

Recommendation 

PUMP RECOMMENDATION FOR 

COPPER-FIN 0986-2066 WATER HEATER 

 

Pump Specifications 

Part No. 

HorsePower 

Flanges 

Valute Material 

Flange Material 

Vendor 

Vendor Product Series 

Orientation 

ARM3024PAB 1/2  2-1/2"  Brass 

Brass Armstrong 

2B1050  Horizontal 

 
Installation Specifications 

  

Recommended for 

 

Based on 

      Pump 

Model Numbers 

Maximum GPM 

Installation Type 

  

Copper-Fin Wtr Htr, CW(N,L) 0986-2066 

90 GPM 

Single Water Heater piped to Single Storage Tank 

ARM3024PAB 

Based on 

Based on 

  

  

Minimum Pipe Diameter 

Connecting piping 

  

  

2-1/2" 

Maximum 45 feet straight pipe with 6-Elbows, 2-Unions,2-Ball Valves and 1-Cold Water Inlet Tee  

IMPORTANT: Read the Copper-fin 495-2065 Installation and Operation Manual.  If the planned system exceeds 
the pump capacity in flow and/or head see “Pump-REC-All Pumps” for alternate pumps and pump curves.   

 
 
 

 

OIL PORT

A

C

16” 

19-1/2” 

 

 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

B

D

11-1/2” 

 
 
 
 
 

 