background image

7

MFH-I&S-02

 CAUTION:

 Operation of this water heater in air contaminated by

perchloroethylene, any chlorinated hydrocarbon or strong oxidizing agents, will result
in serious damage to brass orifices, internal steel parts and void the warranty.

IMPORTANT

 – BURNER MUST BE LEVEL.

 Models containing a cast iron burner

are equipped with an adjustable air shutter. The air shutter on the front of the main
burner must be adjusted when the water heater is installed. See installation instructions
for proper air shutter adjustment procedures.

STATE OF CALIFORNIA NOTICE

 WARNING: 

 This water heater must be braced, anchored or strapped to

avoid falling or moving during an earthquake. See instructions for correct installation
procedures.

 WARNING:

  If not installed, operated and maintained in accordance with

the manufacturer’s instructions this product could expose you to substances in the fuel
or form combustion which can  cause death or serious illness including, cancer, birth
defects or other reproductive harm.

SUITABLE FOR WATER (PORTABLE) HEATING AND SPACE HEATING

Toxic chemicals, such as used for boiler treatment, shall not be introduced into potable
water heater used for space heating. This water heater may never be connected to any
existing heating system or component(s) previously used with a nonpotable water
heater appliance.

THERMOSTAT ADJUSTMENT

The thermostat dial is adjusted to its lowest temperature position when shipped
from the factory.  When adjusting the thermostat it should be remembered
that lower temperature settings are more energy efficient.  To adjust the
thermostat, turn the dial clockwise until the minimum acceptable temperature
is set. It is suggested that the starting point setting not exceed the “HOT” mark
[approximately 120

°

F

 (49

°

 C)

] on the thermostat, as indicated in Figure 2.

 

Figure 2

IMPORTANT

The water heater should be inspected at a minimum annually by a
qualified service technician for damaged components and/or joints
not sealed. DO NOT operate this water heater if any part is found
damaged or if any joint is found not sealed.

 DANGER

Hotter water increases the risk of scald injury.  Scalding may occur within
five (5) seconds at a temperature setting of 135°F 

(57°C)

. To protect

against hot water injury, install an anti-scald tempering valve in the water
system.  This valve will reduce point of discharge temperature by mixing
cold and hot water in branch water lines.  A licensed plumbing professional
or local plumbing authority should be consulted.

Note:  

This water heater is equipped with an energy cut out device to

prevent overheating. Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to the appliance and call
qualified service technician.

Note: 

 Whenever the water heater is filled with cold water, condensate will form on

the cool tank surface and drops of water will fall on the hot burner and combustion
chamber surfaces producing a “sizzling” noise.  Condensation is normal and does
not indicate a leak.  It will disappear when the tank becomes heated.

 WARNING

Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system
and proper care shall be taken to avoid unnecessary contact (especially by
children) with the water heater and vent-air intake system. 

UNDER NO

CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS
GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
VICINITY OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN
ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER
HEATER OR VENT-AIR INTAKE SYSTEM.

Figure 3

BURNER FLAME CHECK

Steel Burner:

  These models are equipped with self adjusting air mixture and

do not have an adjustable air shutter (

See Figure

 3).  At periodic intervals, a

visual check of the main burner and pilot flames should be made to determine
if they are burning properly.  The main burner flame should light smoothly from
the pilot.

MAINTENANCE

The following maintenance should be performed by a qualified service technician
at the minimum periodic intervals suggested below. In some installations, the
maintenance interval may be more frequent depending on the amount of use
and the operating conditions of the water heater. Regular inspection and
maintenance of the water heater and vent-air intake system will help to ensure
safe and reliable operation.

1. Annually check the operation of the thermostat.
2. The flow of combustion and ventilation air 

MUST NOT

 be restricted. Clear

the combustion air openings of any dirt, dust, or other resctrictions.

 WARNING! 

The ventilation air system may be 

HOT.

3. At all times keep the water heater area clear and free from combustible

materials, gasoline and other flammable vapors and liquids.

4. Bi-annually conduct a visual check of the main and pilot burner flames to

determine that they are burning properly.  See Burner Flame Check section
on page 7.

5. Annually remove the inner door and main burner assembly to clean orifices

and related parts of any dirt or other foreign material.  Inspect the burner
ports for obstructions or debris and clean with a wire brush as needed.  Wire
brush and/or vacuum clean the combustion chamber as needed to remove
scale deposits and debris.  

Note:

  It is imperative for proper operation of

the water heater that the inner door be replaced in the original location.

Summary of Contents for MFH-I&S-02

Page 1: ... instructions see page 8 No other components are approved for use with this water heater This water heater has been designed and certified for the purpose of heating potable water The installation and use of this water heater for any purpose other than the heating of potable water may cause damage to the water heater create a hazardous condition and nullify the warranty Do not use this appliance i...

Page 2: ...water heater The drain pan as described above can be purchased from your plumbing professional The drain pan must be piped to an adequate drain The piping must be at least 3 4 inch 1 9 cm in diameter and pitched for proper drainage It is recommended that a minimum clearance of 4 inches 10 2 cm be provided on the side of the water heater for servicing and maintenance of the combination temperature ...

Page 3: ...w the underside sheathing and secure with the screws provided THE BOTTOM OF THE AIR INTAKE MUST BE AT LEAST 12 30 5cm ABOVE THE GROUND LEVEL 4 Seal the openings around the air intake and underside sheathing to resist the entrance of rodents 5 Position the water heater so it is centered above the air intake Note The water heater should also be centered with the openings in the roof and ceiling to a...

Page 4: ...al minutes at the kitchen sink before you use any electrical appliance which is connected to the hot water system If hydrogen is present there will be an unsual sound such as air escaping through the pipes as hot water begins to flow Do not smoke or have open flame near the faucet at the time it is open WARNING For protection against excessive temperatures and pressure install temperatureandpressu...

Page 5: ...mustbeisolatedfromthegassupply piping system by closing its manual shut off valve during any pressure testing of the gas supply system at test pressures equal to or less than psi 3 5kPa The supply line must be capped when not connected to the water heater 3 Change the pilot regulator by removing thermostat dial and pilot regulator cap Depress and rotate knob clockwise to the L P setting using a sc...

Page 6: ...red home mobile home TO FILL THE WATER HEATER 1 Close the water heater drain valve by turning the knob clockwise 2 Open the cold water supply shut off valve 3 Open several hot water faucets to allow air to escape from the system 4 When a steady stream of water flows from the faucets the water heater is filled Close the faucets and check for water leaks at the water heater drain valve combination t...

Page 7: ...verheating Should overheating occur or the gas supply fail to shut off turn off the manual gas control valve to the appliance and call qualified service technician Note Whenever the water heater is filled with cold water condensate will form on the cool tank surface and drops of water will fall on the hot burner and combustion chamber surfaces producing a sizzling noise Condensation is normal and ...

Page 8: ... FOR YOUR SAFETY DO NOT ATTEMPT REPAIR OF COMBINATION GAS CONTROL BURNERS OR GAS PIPING REFER REPAIRS TO A QUALIFIED SERVICE TECHNICIAN WARNING THIS WATER MAY BE HOT 9 A combination sacrificial anode rod hot water outlet nipple has been installed to extend tank life The anode rod should be inspected periodically every 2 years and replaced when necessary to prolong tank life Water conditions in you...