background image

Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN  37090 • 615-889-8900/Fax: 615-547-1000

www.Lochinvar.com

1/07—Printed in U.S.A.

Commercial Electric Steam Boiler Dimensions & Specifications

Top View

Note 1: Element removal clearance (R”) is equal to 2 times the element KW.

Max. Steam

Max.

Connection Sizes (NPT)

Tank Data

Weight

Model Input F&A 212°F # of

Feed

Blowdown

Steam Outlet

Dims

Vol Dimensions (Inches)

(lbs)

Number kW

(PPH)

Elements

Water 15psi >15psi 15psi 50psi 150psi (In)

(Gal)

A

B

C

D

Ship

Oper.

BS*12

60

205

3

1/2"

3/4"

3/4"    1-1/4"

1"

3/4"

12x42

20

22" 28"

50"

25"

550

650

BS*16

140

478

7

1/2" 3/4"

3/4"

2"

1"

3/4"

16x42

32

26" 32"

50"

33"

750

910

BS*16

200

682

10

1/2"

3/4"

3/4"

2" 1-1/4"

3/4"

16x42

32

26" 32"

54"

33"

800

960

BS*20

240

819

12

3/4"

1"

1" 2-1/2" 1-1/4"

1"

20x42

41

30" 36"

50"

51"

1000

1200

BS*20

320

1092

18

3/4"

1"

1"

3" 1-1/2"

1"

20x42

41

30" 36"

54"

51"

1050

1250

BS*24

360

1228

18

3/4" 1-1/4"

1"

3" 1-1/2" 1-1/4"

24x44

74

34" 40"

52"

51"

1300

1670

BS*24

600

2047

30

3/4" 1-1/4"

1"

4" FLG

2" 1-1/2"

24x44

74

34" 40"

56"

51"

1400

1770

BS*30

960

3276

48

3/4" 1-1/2"

1"

6" FLG

3" FLG

2"

30x46

124

40" 48"

60"

63"

1700

2340

BS*36

1280

4367

64

1" 1-1/2"

1"

6" FLG

3" FLG

2"

36x46

166

46" 54"

60"

63"

2100

2960

BS*42

1880

6415

94

1" 1-1/2"

1"

8" FLG

4" FLG

3" FLG

42x48

230

52" 62"

64"

81"

2800

4000

BS*48

2400

8325

122

1"

2"

1-1/4"

8" FLG

5" FLG

3" FLG

48x54

345

58" 63"

70"

87"

4600

6300

BS*54

3040

11598

152

1-1/4"

2"

1-1/4" 10" FLG

6" FLG

4" FLG

54x60

500

66" 74"

76"

89"

5600

8100