Chapter 3: Procedures
3-53
HYDROBAR EXPRESS 220
Top Limiter Adjustment
The purpose of this procedure is to adjust the top limiters.
Tools List:
•
7mm combination wrench
•
.01 feeler gauge or a piece of shim
•
Business card or a small piece of paper
Procedure
Conditions:
•
Main guiding channel open
•
Magazine rack empty
•
Main bar feed power on
Step 1: Confirm that the coder disc is at the referencing position (SQ2 at first hole and the pin in the down position). If the coder disc
is not in position, go to manual mode and press the bar out icon and press and hold the check mark or press the bar in icon.
Step 2: Press the yellow button on the YV7A valve to raise the bar dropping finders to set a reference point for the top limiters.
Step 3: Turn the main bar feed power off.
Step 4: Raise the top limiter by loosening the orange handle and pulling up on the limiter. Tighten the orange handle once the limiter
is raised.
SQ2 at first hole
Pin in down position
Bar out icon
Bar in icon
Orange handle
Press this
yellow button
YV7A
Summary of Contents for Hydrobar Express 220
Page 61: ......
Page 143: ......
Page 147: ......
Page 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Page 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Page 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Page 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...