LM Technologies LM048v2 Pairing Manual Download Page 4

 

LM048v2 and LM058v2 Pairing Procedure document 

 

v1.0 

 

Page 

4

 of 

8

 

©2011 LM Technologies Ltd  

www.lm-technologies.com

 

Time Taken = 30 sec 

3.

 

Connect the Serial cable to the PC and a mini USB to USB cable to the USB port. 

Time Taken = 1 min 

Total time taken for setup = 2 min 30 sec 

2.3

 

Pairing Procedure 

 

1.

 

Unpack the 2 adapters from packaging. Just unpack the adapters. No need to unpack 
accessories. 

Time Taken = 1 min 

2.

 

Make sure slide switch is toward DCE if straight serial cable is used. If twisted cable is used, 
slide switch position is DTE. Connect one adapter to serial port cable and power is via Mini 
USB cable 

Time Taken = 10 sec  

3.

 

Start the LM149 Configuration Software. Select COM port number, 19200 Baud rate, None 
Parity, 1 Stop bits, Flow Control: Disabled 
Press 

Get Device Info

. The LM149 Software will read the settings and update the window 

 

Time Taken = 30 sec 

 

 