IOMVIFB-8
4830 TRANSPORT DRIVE, DALLAS TX 75247
TEL.: (214) 638-6010
www.ljwing.com
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing this equipment.
INSTALLER'S RESPONSIBILITY
Installer Please Note: This equipment has been test fired and inspected. It has been shipped
free from defects from our factory. However, during shipment and installation, problems such as
loose wires, leaks or loose fasteners may occur. It is the installer’s responsibility to inspect
and correct any problems that may be found.
ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
EQUIPMENT. RETAIN FOR FUTURE REFERENCE.
POST AND MAINTAIN THESE INSTRUCTIONS IN LEGIBLE CONDITION.
INSTALLATION, OPERATION AND
MAINTENANCE MANUAL
VERTICAL TUBE HEATING COILS
MV & VIFB MODELS
SAVE THIS MANUAL
ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THESE UNITS! CHECK UNIT DATA PLATE FOR
STEAM OR HOT WATER REQUIREMENTS AND ELECTRICAL SPECIFICATIONS AND MAKE CERTAIN
THAT THESE AGREE WITH THOSE AT POINT OF INSTALLATION. RECORD THE UNIT MODEL AND SE-
RIAL No.(s) IN THE SPACE PROVIDED. RETAIN FOR FUTURE REFERENCE. THE APPLIANCE IS NOT
TO BE USED BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MEN-
TAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO
NOT PLAY WITH THE APPLIANCE.
WING Model No.
Serial No.
Wing MV & VIFB coil performance
is certified by the Air-Conditioning,
Heating, and Refrigeration Institute
(AHRI) under AHRI Standard 410
for maximum working pressures
up to 200 PSIG and temperatures
up to 400° F.
Wing MV & VIFB coils are listed
by Engineering Test Laboratories
(ETL) to Underwriter Laboratories
(UL) Standard 1995. This
standard assures that Wing coils
are safe to operate up to a design
pressure of 100 PSIG.
Summary of Contents for MV
Page 8: ... 8 SECTION VI PARTS DRAWING Enlarged View C Section A A Section D D Elevation ...
Page 11: ... 11 STEAM PIPING VIFB Coil Piping Diagram 15 psig and below W12A ...
Page 12: ... 12 STEAM PIPING VIFB Coil Piping Diagram Above 15 psig W33B ...
Page 13: ... 13 HOT WATER PIPING VIFB Coil Piping Diagram One or Three Row Coils W13B ...
Page 14: ... 14 HOT WATER PIPING VIFB Coil Piping Diagram Two Row Coil W32B ...
Page 15: ... 15 STEAM PIPING MV Coil Piping Diagram 15 psig and below W27A ...
Page 16: ... 16 STEAM PIPING MV Coil Piping Diagram Above 15 psig W28A ...
Page 17: ... 17 HOT WATER PIPING MV Coil Piping Diagram Two Row Coil W29A ...
Page 19: ... 19 ELECTRIC AND PNEUMATIC CONTROLS D000756A ...
Page 23: ... 23 ...
Page 24: ...4830 TRANSPORT DRIVE DALLAS TX 75247 TEL 214 638 6010 www ljwing com ...