Open the carton box and take out the fan (fig. 1). 
Assemble  the  support  plate  on  the  ceiling  using  two  or  more  screw  anchors  and  appropriate  washers. 
Attention: the provided screw are for wood joist and concrete ceiling. (Fig. 2). 
Insert the support rod through the upper cap and lower cap. 
Insert the electric cables coming out from the motor through the support rod and connect them to the screw 
terminal placed on the top of support rod. 
Fix the support rod to the motor using the pin and pin’s nut. (Fig. 3) 
Hang the fan on the hook on the support plate and connect the electrical cable coming from the ceiling to 
the screw terminal placed on the top of support rod, make sure the receiver must be insert into support 
plate (see Remote control connection). 
Slide upwards the upper cap and fix it with the screw. (Fig. 4) 
Slide downwards the lower cap; it must be supported by the motor. Fix it with the screw. (Fig. 4) 
Center the slots on the blades with the heads of the blades fixing screws and slide the blades so that the 
head of the screws are positioned at the end of slot. (Fig. 5) 
Tighten the screw. (Fig. 6) 
Remove the screws from connect plate of the motor, please organize all the wires carefully into connect 
plate.  
Assemble and align the holes on the back of LED light to the three screws on the connect plate of motor. 
(Fig. 7) 
Then tighten the three screws on the LED plate, connect the connector together with the motor wire, please 
make sure the light kit can't be moved after tighten the screws. (Fig. 8) 
Place the lamp shade on the fan (fig. 9) 
 
 

Summary of Contents for DOM445

Page 1: ...Instruction Manual WWW LIVOO FR Reference DOM445 Version 1 4 Ceiling Fan ...

Page 2: ...Instruction Manual 1 Language English ...

Page 3: ...ad manipulation SAFETY INSTRUCTIONS 1 Before connecting your appliance verify that the supply voltage indicated on the indicator plate of the appliance corresponds properly to that of your electrical installation 2 No responsibility may be assumed in case of damages caused by non compliance of this manual by the user or by faulty use or handling 3 This appliance is meant for ONLY DOMESTIC USE and ...

Page 4: ...fan is switched off from the supply mains before removing the guard 10 Do not use chemical products or abrasive detergents for cleaning which may easily damage or deform your appliance 11 Do not place either the fan or its parts near an over a cooking appliance or any other source of heat 12 Do not use the appliance in the presence of explosive or inflammable vapours 13 Never try to disassemble or...

Page 5: ...rate remote control system 21 Do not try to remove the parts and do not insert a metallic object inside the appliance 22 The light source of this luminaire is not replaceable when the light source reaches its end of life the whole luminaire shall be replaced 23 WARNING if unusual oscillating movement is observed immediately stop using the ceiling fan and contact the manufacturer its service agent ...

Page 6: ...o the below paragraph of the manual 30 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses by clients in hotels motels and other residential type environments bed and breakfast type environments Authorised qualified electrician after sales department of the manufacturer or the importer o...

Page 7: ...ent of parts of the safety suspension system device shall be performed by the manufacturer its service agent or suitably qualified persons TECHNICAL SPECIFICATIONS Voltage 220 240V 50 60Hz Fan power 100W Lamp power 18W 3 speed WEIGHT 6 100kg Description Symbol Value Unit Maximum fan flow rate F 177 2 m3 h Fan power input P 48 7W Service value SV 3 6 m3 h W Standby power consumption P SB 0 0W Fan s...

Page 8: ...st 2 3 meters from the floor 2 3 meters means from the floor to the bottom of the fan 0 76m from wall or obstruction Since the installation of the equipment sets the power of the network must be done through Flexible cable plug or by pole switch with contact opening distance not less than 3 mm ...

Page 9: ...Instruction Manual 8 PRODUCT DESCRIPTION Make sure you have all the components before beginning installation To prevent damage first attach the motor to the support rod ...

Page 10: ...Instruction Manual 9 ...

Page 11: ...Instruction Manual 10 ASSEMBLING ...

Page 12: ...all remote control To turn on the ceiling fan you can use remote control to select the desired speed HI High speed MED Medium speed LOW Low speed STOP Turn off the ceiling fan To turn OFF the light push the button LIGHT ON OFF TIMER 1 2 4 and 8 hours for select ...

Page 13: ...ort rod make sure the receiver must be insert into support plate see Remote control connection Slide upwards the upper cap and fix it with the screw Fig 4 Slide downwards the lower cap it must be supported by the motor Fix it with the screw Fig 4 Center the slots on the blades with the heads of the blades fixing screws and slide the blades so that the head of the screws are positioned at the end o...

Page 14: ...of the RED Directive 2014 53 EU Max transmitting power 3 51dBm Frequency range 2402MHz 2480MHz DIRECTIVES RED 2014 53 EU NORMES ou Exigences EN 55014 1 2017 EN61000 3 3 2013 EN61000 3 2 2014 EN55015 2013 A1 2015 EN60335 2 80 2003 A1 2004 A2 2009 EN60335 1 2012 A11 2014 A13 2017 A1 2019 A14 2019 A2 2019 EN62233 2008 EN62368 1 2014 A11 2017 ETSI EN 301 489 ETSI EN 300328 EN62479 Mundolsheim 21 01 20...

Page 15: ...d appliances must be collected separately in order to optimize the recovery and recycling of the materials they contain and reduce the impact on human health and the environment The symbol of the crossed out dustbin is marked on all products to remind the obligations of separate collection Consumers should contact their local authority or retailer for information concerning the correct disposal of...

Reviews: