background image

AIR MASSAGE

Description

Standard Function

The Air Massage has three massage modes and four controllable zones. Each zone 
can be turned on or off, and will disable that zone for each massage mode. If all  

zones are turned off, the Air Massage will turn off. 

The Air Massage is started by pressing the PWR button. The four numerical  

buttons, the MODE button and the PWR button will be lit for the start of the Air  
Massage. Pressing a numerical button will un-light the numerical button pressed  and 
turn off the corresponding zone. 

While the Air Massage is active, it can be turned off at any time by pressing the  

PWR button. 

The Air Massage mode can be changed by pressing the MODE button. There are  

three  massage  modes:  Alternate,  Pulse,  and  Wave.  The  Air  Massage  will  always  
start in the Alternate mode. 

Each massage mode is indicated by the MODE button color. Alternate is Red, Pulse  is 

Green, and Wave is Blue. 

Pressing the numerical buttons or MODE while Air Massage is not active will not  cause 

the system to respond. Air Massage must be active for the numerical buttons  and MODE 
button to control the system. 

The  Air  Massage  has  a  built  in  30-minute  timer.  After  30  minutes  the  Air  Massage  

will  turn  off  and  the  Hand  Control  buttons  will  be  un-lighted.  Pressing  a  numerical  
button or the MODE button will reset the 30-minute timer.

Note

Using the Lumbar function will stop all other massage features. If the massage 
feature is running and either Lumbar button is pressed, the massage will stop.  

Massage can be re-enabled when Lumbar buttons are not pressed.

Hand Wand Manual

Summary of Contents for 1909 CORDOBA POWER ZERO GRAVITY 267665

Page 1: ...1789 BILBAO POWER RECLINER W AIR MASSAGE USER MANUAL...

Page 2: ...Abox shaped unit to transfer 110VAC power to 25V DC power to supply for the furniture JunctionBox splitter extensioncord connecting the power transformer to multiple motors air baddders heat padding...

Page 3: ...lugged in 2 Broken side switch 3 Broken DC socket 4 Broken power transformer especially when ALL motors stops working on one unit 5 Power cords damaged 6 Motors failure NOTE In some cases a button on...

Page 4: ...Instruction for hand wand...

Page 5: ...ted butno heat is produced If the HEAT button is illuminated but the heat pad is not producing heat the heat pad could have become disconnected 1 Unplug the piece of furniture from the wall outlet 2 W...

Page 6: ...ons will be able to be started after 4 seconds pass This is normal operation and should not raise concern Note Using the Lumbar function will stop all other massage features If the massage feature is...

Page 7: ...below 6 Ensure that there are no frayed exposed or otherwise damaged wires Do not connect the motor if the cord is damaged in any way 7 Ensure that there is nothing blocking the path of the motor or c...

Page 8: ...t 2 Wait at least 30 seconds 3 Lift the back panel to reveal zipper pouch 4 Unzip pouch to reveal the Junction 5 Locate the air hose connectors shown below 6 Ensure that the connector is fully mated 7...

Page 9: ...There are three massage modes Alternate Pulse and Wave The Air Massage will always start in the Alternate mode Each massage mode is indicated by the MODE button color Alternate is Red Pulse is Green...

Page 10: ...zipper pouch 4 Unzip pouch to reveal the Junction 5 Locate the air hose connectors shown below 6 Ensure that the connector is fully mated 7 Ensure that the air hoses are not pinched or otherwise bloc...

Page 11: ...POWER RECLINER PARTS...

Page 12: ...cable Check connection security and integrity of motor s 2 pin cable 1 Check power cords integrity and connection to transformer 2 If power cords undamaged and connection secured replace power transfo...