background image

1789 BILBAO POWER RECLINER W/ AIR MASSAGE  

USER MANUAL

Summary of Contents for 1909 CORDOBA POWER ZERO GRAVITY 267665

Page 1: ...1789 BILBAO POWER RECLINER W AIR MASSAGE USER MANUAL...

Page 2: ...Abox shaped unit to transfer 110VAC power to 25V DC power to supply for the furniture JunctionBox splitter extensioncord connecting the power transformer to multiple motors air baddders heat padding...

Page 3: ...lugged in 2 Broken side switch 3 Broken DC socket 4 Broken power transformer especially when ALL motors stops working on one unit 5 Power cords damaged 6 Motors failure NOTE In some cases a button on...

Page 4: ...Instruction for hand wand...

Page 5: ...ted butno heat is produced If the HEAT button is illuminated but the heat pad is not producing heat the heat pad could have become disconnected 1 Unplug the piece of furniture from the wall outlet 2 W...

Page 6: ...ons will be able to be started after 4 seconds pass This is normal operation and should not raise concern Note Using the Lumbar function will stop all other massage features If the massage feature is...

Page 7: ...below 6 Ensure that there are no frayed exposed or otherwise damaged wires Do not connect the motor if the cord is damaged in any way 7 Ensure that there is nothing blocking the path of the motor or c...

Page 8: ...t 2 Wait at least 30 seconds 3 Lift the back panel to reveal zipper pouch 4 Unzip pouch to reveal the Junction 5 Locate the air hose connectors shown below 6 Ensure that the connector is fully mated 7...

Page 9: ...There are three massage modes Alternate Pulse and Wave The Air Massage will always start in the Alternate mode Each massage mode is indicated by the MODE button color Alternate is Red Pulse is Green...

Page 10: ...zipper pouch 4 Unzip pouch to reveal the Junction 5 Locate the air hose connectors shown below 6 Ensure that the connector is fully mated 7 Ensure that the air hoses are not pinched or otherwise bloc...

Page 11: ...POWER RECLINER PARTS...

Page 12: ...cable Check connection security and integrity of motor s 2 pin cable 1 Check power cords integrity and connection to transformer 2 If power cords undamaged and connection secured replace power transfo...

Reviews: