Operating by Remote Handset 

In order to protect the product from becoming too hot, there is an 8s delay when turning on the 

heater; also there is an 8s delay when turning off the heater fan. 

 

Make sure the battery are installed properly in the remote control.

 

The effective range of the remote control is up to 4 meters or 13 feet

 

HEATER BUTTON 

Press once turns Fan on, and 8s later Low heat on. (Pilot lights illuminated ●○) 

Press again turns on High heat. (Pilot lights illuminated ●●) 
Press third time turns heat off. 8s later fan off (Pilot lights illuminated ○○) 
There are 3 levels you can cycle through including the OFF setting. 
 

3.2 Operating by Remote Handset 

 

Make sure the battery are installed properly in the remote control.

 

 

The effective range of the remote control is up to 4 meters or 13 feet.   

 

 

 

 

NOTE: This is thermostatic remote control. The remote should be in the same room as fireplace and placed 
on a flat surface. It must be placed away from the fire so the hot air will not 
blow on it and affect thermostatic reading. 

 
The communication frequency between the fire and remote has already been set 

up.    If you cannot use the remote with the fire, please follow instructions Step 

3.2.34 to initiate this connection in point.   

 
Standby for Remote Handset 

3.2.1  The screen shown to the right is when the remote handset is in   

standby condition.

   

Turn on/off 

3.2.2  Press 

  to  turn  on  the  flame  effect,  turn    off  flame  effect  and  heater 

when in normal mode. 

3.2.3  Press 

  to  turn  on/off  the  flame  effect  under  daily  and  weekly  timer 

mode.                                                                                                                 

 

Summary of Contents for Duvin EF277A

Page 1: ...k neemt De handleiding moet bij de elektrische haard worden bewaard In geval van verkoop aan derden moet deze handleiding worden meegeleverd In geval van onjuist gebruik of het niet volgen van de veil...

Page 2: ...ontactdoos Deze kachel mag niet direct onder een stopcontact Dit apparaat mag worden gebruikt door kinderen vanaf 8 jaar en ouder en personen met verminderde lichamelijke zintuiglijke of geestelijke v...

Page 3: ...output elmin 12 0W standby mode elSB 0 49W Type of heat output room temperature control Single stage heat output and no room temperature control No Two or more manual stages no room temperature contro...

Page 4: ...ooit als een van de onderdelen nat is geweest Neem dan eerst contact op met een gekwalificeerd onderhoudstechnicus voor controle en of vervanging van elektrische onderdelen indien nodig Houd de plasti...

Page 5: ...5 2 2 Afmetingen inbouwhaard Het evt maken van een frame voor de inbouwhaard...

Page 6: ...n deze montagebeugels eerst gedemonteerd worden Bewaar de montagebeugels en schroefjes goed deze heeft u later nodig STAP 2 Kies een solide wand waar u de montagebeugel tegenaan plaatst Markeer met ee...

Page 7: ...de haard aan de wand en bevestig de haard met de montagebeugels aan de onderzijde STAP 5 Verwijder de twee draaischroefje aan de bovenzijde van de haard en haal heel voorzichtig het glas uit de haard...

Page 8: ...8 STAP 6 Maakt u de haard ook aan beide zichtbaar plaats dan de zijruiten met de meegeleverde montagebeugels...

Page 9: ...handmatige bediening Belangrijk De handmatige functietoets heeft niet dezelfde uitgebreide mogelijkheden als de afstandsbediening Het doel is om de belangrijkste functies te kunnen bedienen ingeval d...

Page 10: ...rbinding zijn verbroken volg dan stap 3 2 24 Standby functie afstandsbediening 3 2 1 Het display links geeft het beeld aan als de afstandsbediening in standby staat Aan uit zetten van de haard 3 2 2 D...

Page 11: ...st Tijdzone 24 uurs systeem Selecteer de comfort warmte tussen de 15 en 25 graden U kunt kiezen tussen Celcius en graden Fahrenheit Dagelijkse timer functie 3 2 16 De volgende tijdszone zijn de standa...

Page 12: ...oor afstandsbediening is noodzakelijk als het apparaat verkeerd werkt of de afstandsbediening niet correct werkt Open de achterklep van de afstandsbediening Druk op de Reset knop op de afstandsbedieni...

Page 13: ...een vloeistoffen direct op elk oppervlak van het toestel Waarschuwing een erkende monteur moet ander onderhoud uitvoeren 4 4 Milieu Gooi elektrische apparaten als ongesorteerd afval gebruiken gescheid...

Page 14: ...ture reference This manual is part of the device and should be stored with it In case of sale to a third party these instructions for use should be supplied with the product Liability will not be acce...

Page 15: ...mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved In order to...

Page 16: ...standby mode elSB 0 49W Type of heat output room temperature control Single stage heat output and no room temperature control No Two or more manual stages no room temperature control No With mechanic...

Page 17: ...alified service technician to inspect and to replace any part of the electrical system if necessary Keep plastic wrapping away from children Open the packaging carefully and remove the foam Remove and...

Page 18: ...18 2 2 Dimensions insert fireplace Built in installation of insert fireplace Note Ensure that you leave adequate room to remove and replace the front screen or optional front...

Page 19: ...he Wall Mounted Brackets in the position where you want to install the fireplace Mark the holes by a pen from the holes on the bracket Then drill 8 holes on the wall If the wall is solid wood it is no...

Page 20: ...rews on the position you marked Lay the unit down on flat floor fix the power cord on the right bottom of the unit and hang the unit on the wall mounted bracket and fixing brackets by STAP 5 Take out...

Page 21: ...5 3 to 5 5 5 10 Use the Top left right bracket for two sides visible Bottom right bracket for two sides visible to replace the brackets which are used on the right side of the Firebox meanwhile repla...

Page 22: ...ction control and its propose is to control some basic function when you lose the remote handset Please use the remote hand set to carry out all functions NOTE The flame will always on when the applia...

Page 23: ...ure the battery are installed properly in the remote control The effective range of the remote control is up to 4 meters or 13 feet NOTE This is thermostatic remote control The remote should be in the...

Page 24: ...the fan heater to stop running for periods of time This happens because the room temperature is at or above the temperature set on the remote control The heater indicator will be turned off after 10s...

Page 25: ...3 2 21 To check your daily timer settings press 3 2 22 If heating needs to be turned off it will be necessary to go back to the Normal Mode to turn off Week Timer Heating 3 2 23 The following are pres...

Page 26: ...nsmitter detects a rapid drop in room temperature it will be judged as a window open the warning icon will be displayed and the heating will be turned off automatically 3 2 33 After the indoor tempera...

Page 27: ...liance has cooled down and the appliance has been reset Re setting of the E S Control proceeds is as follows 3 2 37 Switch off the appliance Manual On Off switch and leave it off for approximately 10...

Page 28: ...Caution Do not use abrasive cleaners on the glass panel Do not spray liquids directly onto any surface of the unit 4 3 Environment Meaning of crossed out wheeled dustbin Do not dispose of electrical...

Page 29: ...anuel de montage et mode d emploi Duvin Chemin e insert lectrique Veuillez lire attentivement l ensemble du pr sent manuel de montage et mode d emploi avant d installer le foyer et de le mettre en ser...

Page 30: ...is par des enfants g s de 8 ans et plus et des personnes dont les capacit s physiques sensorielles ou mentales ou manquant d exp rience et de connaissances si elles ont t form es et encadr es pour l u...

Page 31: ...power consumption 2KW Power for flame effect Noville 9 5W LED 5 5W Motor for flame 4W Power for Fuel Bed 5 5W LED 1 5W Motor for flame 4W Heat Output Nominal heat output Pnom 2KW Minimum heat output i...

Page 32: ...ement un technicien de service qualifi pour inspecter et pour remplacer toute pi ce de la lectrique syst me si n cessaire Gardez en plastique enveloppant la port e des enfants Ouvrez l emballage avec...

Page 33: ...33 Dimensions Installation instructions Remarque Veillez laisser suffisamment d espace pour retirer et remplacer l cran avant ou le panneau avant optionnel...

Page 34: ...x dans la position o vous souhaitez installer le foyer Marquez les trous par les trous sur le support Ensuite percez 8 trous sur le mur Si le mur est en bois massif il n est pas n cessaire de percer l...

Page 35: ...es vis sur la position marqu Posez l appareil sur un sol plat fixez le cordon d alimentation en bas droite unit et accrocher l unit sur le support mural et les supports de fixation par STAP 5 Retirez...

Page 36: ...veuillez suivre les tapes 5 3 5 5 5 10 Utilisez le support sup rieur gauche droit pour les deux c t s visibles et le support inf rieur droit pour les deux c t s visibles pour remplacer les supports su...

Page 37: ...onctionnement Bouton manuel REMARQUE Le bouton manuel sur l unit de la bo te feu vous donne pas tous les contr les de fonction et son proposer est de contr ler certaines fonctions de base lorsque vous...

Page 38: ...ne La fr quence de communication entre la t l commande et le po le est pr r gl e automatiquement Si la connexion est interrompue suivez les instructions de l tape 3 2 24 Fonction de veille de la t l c...

Page 39: ...rtant la fonction de chauffage se d sactive automatiquement d s que la temp rature souhait e dans la pi ce est atteinte R glage de la date de l heure et de la temp rature de confort 3 2 13 Appuyez sur...

Page 40: ...et un avertissement de fen tre ouverte La fonction de chauffage est alors activ e automatiquement R glage de la fr quence entre le po le et la t l commande 3 2 24 Les op rations ci dessous doivent tre...

Page 41: ...prise de courant Laissez d abord refroidir le po le 4 3 T L COMMANDE Pile pleine Pile moiti pleine Les piles sont vides et doivent tre remplac es imm diatement Au bout de 1 an il est recommand de remp...

Page 42: ...par des appareils neufs le commer ant est tenu l galement de reprendre votre ancien appareil des fins de d sinvestissement au minimum titre gratuit Ce po le r pond aux normes de s curit EN 60335 1 et...

Page 43: ...unmittelbarer N he des Elektrokamin aufbewahrt werden Beim Weiterverkauf muss diese Anleitung mitgeliefert werden Bei nicht bestimmungsgem em Gebrauch oder Nichtbeachtung der Sicherheitsvorschriften i...

Page 44: ...r Steuerschaltung die regelm ig ein und ausgeschaltet durch Gebrauchsmuster Das Heizger t darf nicht unmittelbar unter einer Steckdose befinden Das Ger t kann von Kindern ab 8 Jahren und dar ber und P...

Page 45: ...o Kinder und gef hrdete Personen vorhanden sind Nicht abdecken Um eine berhitzung zu vermeiden decken nicht die Heizung Die Bedeutung der Zahl in Kennzeichnung ACHTUNG NICHT COVER Wenn das Netzkabel b...

Page 46: ...LED 8 58W Motor for flame 4W Power for Fuel Bed 7 84W LED 3 84W Motor for flame 4W Heat Output Nominal heat output Pnom 2KW Minimum heat output indicative Pmin 1KW Maximum continuous heat output Pmax...

Page 47: ...rpr fen und zu ersetzen einen Teil der elektrischen System gegebenenfalls Halten Plastikverpackung von Kindern fern Verpackung vorsichtig ffnen und entfernen Sie den Schaum Entfernen und Entsorgen der...

Page 48: ...ie eine feste Wand und befestigen Sie die Wandhalterungen an der Stelle an der Sie den Kamin installieren m chten Markieren Sie die L cher durch die L cher in der Halterung Bohren Sie dann 8 L cher an...

Page 49: ...n Schornstein an der Wand stellen Sie die Halterungen an der Wand ein Schalte dann den Schornstein aus und befestige die Halterungen mit Schrauben an der markierten Stelle Stellen Sie das Ger t auf ei...

Page 50: ...50 STAP 5 Entfernen Sie die M5 12 Schraube von beiden Seiten und legen Sie die St mme und Steine entlang der Aussparung an der Vorderseite der Brennkammer...

Page 51: ...lgen Sie bitte den Schritten 5 3 bis 5 5 5 10 Verwenden Sie die obere linke rechte Halterung f r beide sichtbaren Seiten und die untere rechte Halterung f r beide sichtbaren Seiten um die Halterungen...

Page 52: ...ng beim Einschalten der Heizung auch gibt es 8s Verz gerung beim Ausschalten des Heizgebl se 3 1 Betriebssystem durch manuelle Knop HINWEIS Die manuelle Taste auf der Feuer Kiste Ger t nicht versorgen...

Page 53: ...min befindet und auf einer ebenen Fl che stehen Die Kommunikationsfrequenz zwischen Fernbedienung und Kamin wird automatisch voreingestellt Wenn die Verbindung unterbrochen ist befolgen Sie Schritt 3...

Page 54: ...schalten Im Display unten steht jetzt ON OFF Wichtig Die Heizfunktion schaltet sich automatisch ab wenn die gew nschte Raumtemperatur erreicht ist Einstellung von Datum Uhrzeit und Komforttemperatur 3...

Page 55: ...ann automatisch eingeschaltet Einstellen der Frequenz zwischen Kamin und Fernbedienung 3 2 24 Die nachstehend aufgef hrten Vorg nge sind vor der Programmierung beim Umschalten auf eine neue Fernbedien...

Page 56: ...ins ein weiches feuchtes fusselfreies Tuch benutzen Verwenden Sie keine Reinigungsmittel oder polierten Produkte Um Fingerabdr cke oder andere Flecken auf der Frontglasscheibe zu entfernen verwenden S...

Page 57: ...den Anforderungen der Europ ischen Elektromagnetischen Komptabilit t 2014 30 EU und die RED Normen EN300220 2 EN301489 1 EN301489 3 und EN6247 erf llen und auch den Anforderungen der europ ischen Funk...

Reviews: