Livestrong LS9.9E Service Manual Download Page 7

7/10 

CHAPTER 3: ENGINEERING MODE 

3.1Engineering Mode 

1)

To enter Engineering Mode, press & hold the resistance UP and DOWN keys (Figure B) at the same time for 3-5

seconds until Engineering Menu appears on the display. 

2)

Use the INCLINE and RESISTANCE UP and DOWN keys to select a parameter.

3)

Press ENTER to enter a parameter setting.

4)

Use the INCLINE and RESISTANCE UP and DOWN keys to change the parameter.

5)

Press and hold the STOP key to exit Engineering Mode and return to normal operation.

(

Figure B)

3.2 Engineering Mode Overview

MODE

 

Function

 

Description

 

ENG 0 

Display 
Test 

Start Key - LED on 
Stop Key - LED off 
Any Other Key - Will show on the display window.     
Hold the STOP key for 3 seconds to return to the Engineering Menu. 

ENG 1 

Hardware 
Test 

Resistance up-ECB counter up in resistance window 
Resistance down-ECB counter down in resistance window 
Heart signal in-display the heart value in heart window 
RPM signal in-display the PRM value in RPM window 
Hold “STOP” 3 sec  back to Engineering Mode

 

ENG 2 

Switch 
Function 

Use the INCLINE or 

RESISTANCE

UP and DOWN keys to switch DEMO MODE off or on. 

Use the START key to select unit (1=KM, 0=Mile).     

ENG 3 

Information 

Accumulated Time and Distance
Press and hold the START key for 5 seconds to clear all data. 

ENG 4 

Incline test 

Press ENTER – save the ADC value
Press INCLINE or UP and DOWN – change the incline value. 

CHAPTER 4: ERROR CODE 

There are no ERROR CODE define in this model. 