CHAPTER 2: ENGINEERING MODE
2.2 Engineering Mode Overview
Mode
Function
Description
Eng 0
Display Test
GO
LCD on
STOP
LCD off
Press any other key to test for function.
Hold “STOP” 3 sec
back to “Engineering Menu”
Eng 1
Hardware Test
Press ENTER to scroll through the options in this menu and LEVEL UP
or DOWN to test or change the settings / components below.
ECB Count – Allows testing of the ECB motor.
Incline – Allows testing of the incline motor.
Heart – Allows for testing of the heart rate.
MCB Ver – Shows the software version of the MCB. Not Editable.
USB On / Off – This setting will automatically display on or off
depending on if there is a USB in the USB port.
Hold “STOP” 3 sec
back to “Engineering Menu”
Eng 2
Switch Function
Use INCLINE up and down to choose SPEED MODE.
ENTER
Use INCLINE up and down to switch EUP on or off.
ENTER
Use INCLINE up and down to choose US or ID
Hold “Stop” 3 sec
back to “Engineering Menu”
Eng 3
Information
Press ENTER to scroll through the options in this menu and LEVEL UP
or DOWN to test or change the settings / components below.
Speed Mode – Miles or Kilometers.
EUP On / Off – EUP = Energy Using Products Directive.
Machine Set – Set the region of the customer (US or ID (international)).
Hold “Stop” 3 sec
back to “Engineering Menu”
ENG8
While in ENG2, Hold LEVEL UP and DOWN for
3 sec to enter ENG8.
P0 in distance window = the current software
P1 in distance window = accelerated ratio (factory only setting).
P3 in distance window = Hold START key for 3 sec to clear all console
data.
P4 in distance window = Burn Time (factory only setting).
Hold “Stop” 3 sec
back to “Engineering Menu”
※
“
START
” key to save the change.