background image

Using LiveWire Edge

Network Monitoring

For network monitoring, LiveWire Edge is used 
together with LiveNX. LiveWire Edge is 
connected to the network and configured to 
send data to LiveNX (this data is called 
LiveFlow), and LiveNX collects network 
statistics from one or more LiveWire Edge 
devices for long-term reporting and trending. 
Understanding the network and solving 
problems is extremely visual using LiveNX, and 
with its unique integration to network packets 
stored on the LiveWire Edge devices, you have 
access to the detailed data required for 
immediate root-cause analysis.

Network Troubleshooting

LiveWire Edge can also be used as a 
stand-alone network packet recording and 
analysis device. LiveWire Edge includes a copy 
of Omnipeek

®

, LiveAction’s premier software 

for understanding network performance and 
operation based on solely packet data. A web 
browser version of Omnipeek is also built-in, 
which any number of users can connect to at 
the same time. With Omnipeek and LiveWire 
Edge, you can capture and decode packets 
and interact with high level visualizations to 
understand network and application 
performance, VoIP performance, user activity, 
security issues, and much more.

The registered owner can download the latest 
version of Omnipeek from their MyPeek 
account at: 

https://mypeek.liveaction.com

LiveNX Integration

To use LiveWire Edge to export LiveFlow data 
to a LiveNX server, go to Captures > + New 

LiveFlow Capture in the Omnipeek Web interface, 
and adjust any configuration settings as needed. 
You will also need to specify router mappings if 
you use the bridge ports for the capture.

Additionally, in the LiveNX application, when 
adding a LiveWire Edge device to LiveNX from the 
Add Device dialog, configure the 'Enter SNMP 
connection settings for this device' option as 
follows:

SNMP Version: 

Version 3

User Name: 

admin

Authentication Protocol: 

SHA

Authentication Password: 

Ys2Q5Xxu7g3gUoHxfUFifqiXSXjd2tkc

Privacy Protocol: 

AES 128-bit

Privacy Password: 

x3Fmpv9OpIsnk0Qg3rH25BKBd66fxzSK

Reset to Factory Defaults

In the event you need to reset LiveWire Edge to its 
factory settings, use a paper clip or similar object 
to hold down the reset button for three seconds. 

If any settings need to be changed after reset, 
the configuration utility will need to be run again.