background image

16

MOD.

Ø EXIT HOLE  

(mm)

SUCTION 

(m

3/

h)

AM90

150

1000

AM120

150

1000

INSTALLATION

911- 1216  mm

560 mm  

880  mm 

480 mm 

ø150/200 mm

ø150/200 mm

400 mm 

220/240 V

50 Hz

380 mm 

400 mm

911- 1216  mm

560 mm  

880  mm 

480 mm 

ø150/200 mm

ø150/200 mm

400 mm 

220/240 V

50 Hz

380 mm 

400 mm

Summary of Contents for PANORAMAGIC APM120

Page 1: ...HOODS PANORAMAGIC APM90 APM120 USER Use and Maintenance INSTALLER Installation manual cod EI33960370000EN 08 2021 EN ...

Page 2: ......

Page 3: ... INFORMATION IMPORTANT SAFETY WARNINGS INSTRUCTIONS FOR USE CLEANING AND MAINTENANCE PERIODS OF INACTIVITY ORDINARY MAINTENANCE replacement of the spotlight IMPORTANT SAFETY WARNINGS INSTALLATION IMPORTANT SAFETY WARNINGS INSTALLATION INSTALLER 14 26 ...

Page 4: ...l guide you through starting using the hood quickly and without difficulty We therefore recommend that you read it carefully before use and that you store it carefully for futurereference We remain at your full disposal for any further information that you may require or if you have any problems in understanding any contents of this booklet ILVE S p a Via Antoniana 100 35011 Campodarsego PD Italy ...

Page 5: ... tuation that might cause injuries or death Read the instruction manual Useful advice and information Reference to another chapter The Manufacturer reserves the right to make improving modifications to the equipment or accessories at any time Partial reproduction without th Manufacturer s authorization is forbidden The measure ments given are indicative and not binding ICON ATTENTION ...

Page 6: ...non genu ine spare parts supplied by ILVE S p a Il presente apparecchio può essere utilizzato dai bambi ni a partire dagli 8 anni e da persone con ridocce capa cità fisiche sensoriali o mentali oppure con mancanza di esperienza e di conoscenza se sitrovano sotto ade guata sorveglianza oppure se sono stati istruiti circa l uso dell apparecchio in modo sicuro e se si rendono conto dei pericoli corre...

Page 7: ...sonal protective equipment e g gloves safety footwear etc after the surfaces of the hood have COOLED DOWN always wear appropriate personal protective equipment i e gloves safety footwear etc Failure to follow the instructions or the use of unsuitable cleaning devices may pose a risk of fire and or damage to the hood or the surrounding objects so the Manufacturer couldn t be held responsible egular...

Page 8: ...tched on at least a couple of minutes before starting to cook to promote the suction of fumes and steam After finishing cooking leave the hood in operation for an extra few minutes in this case it may be appropriate to activate the Timer function which automatically switches the hood off after 10 minutes The page that follows shows how to use the control panel What speed should I use The unit oper...

Page 9: ...sts the motor at full speed for 5 minutes and after that automaticalty returns to the third speed TIMER FUNCTION By pressing the TIMER push button while the hood is working the clock symbol will start flashing Once the timer is set the hood will continue working for about 10 minutes and then it will automatically switch off The timer can be switched off at any moment by pressing its push button In...

Page 10: ...trol connected to the light enables the red led light for half a second Coupling with the remote control of the hood When enabling the hood in the tirsi 7 seconds push the ON OFF button on the remote control for two seconds In this way the remote contrai will be coupled and activated After the tirsi 7 seconds the programming of the hood will be tinished and the coupling will be protected tram exte...

Page 11: ...riatic or sulphuric acid abrasive or sharp tools e g abrasive sponges scrapers steel brushes etc water sprays The INSIDE and the OUTSIDE of the hood should be cleaned solely by using a damp cloth with little neutral soap It is also possible to use a steel specific cleanser paying attention to the instructions written on the canister or bottle To conclude the cleaning operation rinse using a clean ...

Page 12: ...hat the maximum temperature is 70 C 158 F higher temperature can cause darkening in the metal please note that this DOES NOT impair the operation of the filter For their removal see Fig 5 ACTIVE CARBON FILTERS These filters cannot be washed or regenerated and should therefore be replaced every 3 to 4 months depending on the hood usage Damp environments high temperature soiled anti grease filters a...

Page 13: ...aseline oil to all stainless steel surfaces At first use accurately clean the equipment reconnect the power supply ALWAYS MAKE SURE THAT THE APPLIANCE IS DISCONNECTED FROM THE NETWORK 1 Lower the steel panel and remove the filters 1 2 2 Press the tabs and push the LED bar outwards 4 Disconnect and replace the led bar PROCEDIMENTO DA SEGUIRE 2 1 Fig 5 ORDINARY MAINTENANCE LED bar replacement ...

Page 14: ... power supply cord is too short have a qualified electrician install an outlet near the appliance WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO PROVIDE PROTECTION AGAINST ELECTRIC SHOCK CONNECT TO PROPERLY GROUNDED OUTLETS ONLY WARNING there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels not ap...

Page 15: ...be replaced by the manufacturer its ervice agent or similarly qualified persons in order to avoid a hazard Before installing the equipment carefully read the safety instructions page 6 and the indications provided from page 14 IMPORTANT SAFETY WARNINGS ...

Page 16: ... AM90 150 1000 AM120 150 1000 INSTALLATION 911 1216 mm 5 6 0 m m 880 mm 480 mm ø150 200 mm ø150 200 mm 400 mm 220 240 V 50 Hz 380 mm 400 mm 911 1216 mm 5 6 0 m m 880 mm 480 mm ø150 200 mm ø150 200 mm 400 mm 220 240 V 50 Hz 380 mm 400 mm ...

Page 17: ...17 INSTALLER ø8 mm UTENSILI NECESSARI CONTENUTO IMBALLO ø 05 16 40 mm 137 64 45 mm 149 64 x2 x4 10 mm 025 64 x 4 INSTALLATION NECESSARY TOOLS PACKAGE CONTENT ...

Page 18: ...mm ø 05 16 The fastening kit screws and plugs supplied with the hood can only be used on masonry wall For installation on other types of walls consider alternative fastening systems taking into a count the strength of the wall itself and the wei ght of the hood INSTALLATION ...

Page 19: ...19 INSTALLER STEP 2 STEP 3 2 1 OK INSTALLATION ...

Page 20: ...20 INSTALLATION STEP 4 STEP 5 1 3 4 2 2 1 ø8 mm ø 05 16 40 mm 137 64 ...

Page 21: ...21 INSTALLER INSTALLATION STEP 6 ...

Page 22: ...mpare the system data with that printed on the data plate check all the components for integrity and functionality in case of fault stop the installation and contact the distributor Do no connect the product to the power main before any other step of the installation is completed Any interventions tampering or modifications not expressly authorised not complying with the content of this manual wil...

Page 23: ...ectric connection socket must be easy to reach even after installation of the equipment Should this not be the case a general switch must be installed in order to disconnect the hood from the power supply in case of need The maximum weight of any objects placed on top of the hood or attached to the same should not exceed 2 kg 4 4 lb The air must not be discharged into a flue that is used for exhau...

Page 24: ...al or a steel specific cleanser only All packaging and the protective film must be disposed of in accordance with the regulations of the country of use Always make sure that nothing is disposed of in the environment Packaging materials may be potentially dangerous for children and animals HOW TO READ PRODUCT LABEL The product label is located inside the hood usually attached on its bottom being vi...

Page 25: ...workplace safety regu lations The equipment must only be installed by respon sible and experienced adults without physical impairment and in perfect psychological and physical condition During installation anyone and any objects not involved in the assembly operations must be kept away from the area Before starting the assembly operations make sure that all the necessary tools are available and in...

Page 26: ...responsibility Make sure that the flue is in perfect working order and that a square concrete or round metal static wind break ventilation tower with useful output section not less than double the diameter of the flue UNI 7129 is instal led at the top of the flue itself Comply with all air discharge regulations The drain chimney of the building should be dedicated to the hood only so under no circ...

Page 27: ......

Page 28: ...28 ...

Reviews: