![Little Giant PONY 360 Instructions Manual Download Page 7](http://html1.mh-extra.com/html/little-giant/pony-360/pony-360_instructions-manual_1929101007.webp)
the groove on the inlet plate before reassembly. Carefully reinsert the mounting screws, taking care not to cut new
threads or strip the screw holes.
2.
When connected in-line, slope the hose or pipe connection upward from the pump inlet to the water supply. A
flooded suction is necessary for pump to operate.
3.
If the surface is dirt or sand, place the pump on a flat object (such as a piece of wood or metal) to prevent it from
being clogged.
4.
Support the weight of the pump adequately. DO NOT support the pump by the intake or discharge connections
alone.
5.
Do not restrict the intake side of the pump. This can damage the seal and starve the pump. To reduce the flow, place
a valve on the discharge side of the pump or, if flexible vinyl tubing is used, a clamp on the tubing.
6.
If the pump will be idle for an extended period, clean it according to the MAINTENANCE section. Do not let the pump
freeze in the wintertime. This can cause cracking or distortion that will damage the pump.
MAINTENANCE
WARNING:
DISCONNECT THE PUMP FROM THE POWER SOURCE BEFORE
SERVICING OR REMOVING ANY COMPONENT.
CAUTION:
The pump is permanently lubricated. Oiling is not required. DO NOT open the sealed portion of the pump or
remove the housing screws.
NOTE:
The power leads on this pump cannot be replaced; if they become damaged the entire pump must be replaced.
Clean the pump periodically to prolong its life and efficiency:
1.
Disconnect the black negative (–) lead wire, then disconnect the red positive (+) lead wire.
2.
Checktheleadwirestoensurethattheyareingoodconditionwithnonicksorcuts.
3.
Remove the volute mounting screws, then remove the volute from the pump. DO NOT remove any other screws.
4.
Lightly clean any corrosion or debris that may clog the impeller. Use a brush and penetrating oil and lightly scrape
to remove encrusted material.
5.
Turn the impeller by hand to make sure it turns freely.
6.
Place the pump on a solid surface, ensuring that the pump and impeller are not touching anything. Connect the
pump to 12VDC power source for 10 seconds. If the impeller rotates, disconnect the pump from the power
source and install the parts in reverse order. If the impeller does not rotate or the pump does not operate
properly, return the pump to Franklin Electric or an authorized service center. DO NOT attempt repairs yourself.