Little Giant PONY 360 Instructions Manual Download Page 7

 

the groove on the inlet plate before reassembly. Carefully reinsert the mounting screws, taking care not to cut new 

threads or strip the screw holes.  

2.

 

When connected in-line, slope the hose or pipe connection upward from the pump inlet to the water supply. A 

flooded suction is necessary for pump to operate.  

3.

 

If the surface is dirt or sand, place the pump on a flat object (such as a piece of wood or metal) to prevent it from 

being clogged.  

4.

 

Support the weight of the pump adequately. DO NOT support the pump by the intake or discharge connections 

alone.  

5.

 

Do not restrict the intake side of the pump. This can damage the seal and starve the pump. To reduce the flow, place 

a valve on the discharge side of the pump or, if flexible vinyl tubing is used, a clamp on the tubing.  

6.

 

If the pump will be idle for an extended period, clean it according to the MAINTENANCE section. Do not let the pump 

freeze in the wintertime. This can cause cracking or distortion that will damage the pump.  

 

MAINTENANCE 

 

WARNING: 

DISCONNECT THE PUMP FROM THE POWER SOURCE BEFORE  

SERVICING OR REMOVING ANY COMPONENT.  

CAUTION: 

The pump is permanently lubricated. Oiling is not required. DO NOT open the sealed portion of the pump or 

remove the housing screws.  

NOTE: 

The power leads on this pump cannot be replaced; if they become damaged the entire pump must be replaced.  

Clean the pump periodically to prolong its life and efficiency:  

 

1.

 

Disconnect the black negative (–) lead wire, then disconnect the red positive (+) lead wire.  

2.

 

Checktheleadwirestoensurethattheyareingoodconditionwithnonicksorcuts.  

3.

 

Remove the volute mounting screws, then remove the volute from the pump. DO NOT remove any other screws.  

4.

 

Lightly clean any corrosion or debris that may clog the impeller. Use a brush and penetrating oil and lightly scrape 

to remove encrusted material.  

5.

 

Turn the impeller by hand to make sure it turns freely.  

6.

 

Place the pump on a solid surface, ensuring that the pump and impeller are not touching anything. Connect the 

pump to 12VDC power source for 10 seconds. If the impeller rotates, disconnect the pump from the power 

source and install the parts in reverse order. If the impeller does not rotate or the pump does not operate 

properly, return the pump to Franklin Electric or an authorized service center. DO NOT attempt repairs yourself.  

 

Summary of Contents for PONY 360

Page 1: ...FNPT IP 53 Capacity 1136 LPH 31m Shut Off 14 m Discharge 19 mm Electrical 12VDC 60Hz 7 0A 165W MODEL 555203 BPLA Utility Pump Water removal from compact places such as boat bilges recreational vehicl...

Page 2: ...not compatible with pump component materials Do not use unit in enclosed areas Intermittent duty only 15 minutes per hour SAFETY GUIDELINES WARNING Do not use to pump flammable or explosive fluids su...

Page 3: ...of the wide variety of applications and mounting situations an inline fuse has not been permanently installed In order to provide adequate protection for the motor an inline fuse and fuse holder MUST...

Page 4: ...Consult your local electrician for installation and availability 11 When used in a boat pump should not be installed in the bilge WARNING Disconnect battery when making adjustments and repairs First...

Page 5: ...cemen should attempt to repair this unit Improper repair and or assembly can cause an electrical shock hazard 5 TO REPLACE IMPELLER Replace impeller when it has become worn or damaged 6 Remove cover p...

Page 6: ...or clothing flush immediately with large amounts of water and get medical attention Do not add acid or electrolyte to the battery Keep out of reach of children In any installation where property dama...

Page 7: ...SERVICING OR REMOVING ANY COMPONENT CAUTION The pump is permanently lubricated Oiling is not required DO NOT open the sealed portion of the pump or remove the housing screws NOTE The power leads on th...