background image

ELECTRICAL CONNECTIONS

1. If the pump is supplied with a three prong electrical plug, the third prong is to ground the motor to prevent possible

electrical shock hazard. Do not remove the third prong from the plug. The receptacle should be the three prong

polarized type with an internal ground. A separate branch circuit is recommended. Do not use an extension cord.

Do not cut plug from cord, this will void the warranty.

2. If the motor has either individual lead wires and conduit connection box, or power cord with stripped lead wires, be

sure that the wires are connected to proper power supply source. Use the conduit box on motor (if applicable) to

connect conduit pipe to protect individual lead wires. Color code will either be: black: (live) white (common)

green (ground) or brown (live) blue (common) green/yellow (ground).

IMPORTANT – Read pump label for correct voltage of pump motor. Make sure proper voltage is supplied to motor.

SERVICE

Very little service is required by the CMD-100 pumps. Sleeve bearing motors require lubrication once a year at the begin-

ning of the season using an SAE 20 weight non detergent oil. If the pump is to be used year round; it should be oiled

every six months. Do not over oil. Three or four drops should be sufficient. No lubrication is necessary for ball bearing mo-

tor models. Position motor so oiler tubes are located on upper portion of motor.
The circulator pump is comprised of two main sections, (1) the pumping head and (2) the drive motor. The pumping head

includes: the volute, thrust bearing, impeller shaft, o-ring seal, impeller assembly, stainless steel backplate and housing.

The drive motor includes the motor and the drive magnet assembly. To separate the two sections, remove the three

screws which attach the pump head to the motor. Only three screws have been used by the factory to permit easy assem-

bly and disassembly. Liquid will still be contained on the pumping head, and will not be drained unless you loosen the four

screws that attach the brass volute to the housing. The pump head must be realigned on the motor drive assembly before

the pump is put back into service.

SPECIFICATIONS

Catalog No.

Model No.

Flow

@ 1 Ft.

(GPM)

Max.

Head

(Ft.)

Max.

PSI

Inlet/

Outlet

(MNPT)

Imp.

Dia.

Motor Data

Wt.

Total

(Lbs.)

Volts

Hertz

RPM

Phase

HP

Watts

Amps

579000

CMD-100-3B

3

4.0

1.73

1/2"

2.00" 115

60

1550

1

1/125

35

.43

4.8

579200

CMD-100-5B

6.2

12.0

5.2

1/2"

1.69" 115

60

3000

1

1/25

81

.60

6.5

CMD-100-5B

CMD-100-3B

·

1550 RPM MOTOR

·

BRASS PUMP HEAD

·

CONDUIT BOX

·

DUAL FAN

·

15" LEAD WIRES

·

3000 RPM MOTOR

·

BRASS PUMP HEAD

·

BASE BRACKET

·

DUAL FAN

·

6 FT. SJT CORD ON 115V