Little Giant 12E Series Owner'S Manual Download Page 1

12E Series Effluent Pump

OWNER'S MANUAL

English

EN

This submersible pump is designed for use in basins or pumping stations and is suitable for pumping clean 
water or effluent gray water with up to 3/4" (19 mm) spherical semi-solids. Do not use the pump in appli

-

cations where sewage or any other debris (gravel, sand, floating debris, etc.), abrasives, or corrosives are 
present.
The pump motor is equipped with an automatic restart thermal protector and 
may restart unexpectedly. Activation of the thermal protector indicates that the 
motor is overloaded or overheated, which may be due to application problems, 
such as a clogged pump impeller, a switch stuck in the on position, a dry running 
of the pump, a air-sealed pump, a short pump cycle, an excessively high or low 
voltage supply, or a pump, motor, bearings, or seal that may have reached the 
end of its useful life.
This product is covered by a Limited Warranty for a period of 36 months from the 
date of original purchase by the consumer. For complete warranty information, 
refer to 

www.LittleGiant.com

.

Specifications

SAFETY INSTRUCTIONS

This equipment should be installed and serviced by technically qualified personnel who are familiar with 
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with 
national and local electrical and plumbing codes and within Little Giant recommendations may result in 
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to 
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following 
hazards:

Model

HP

Volts

Hz

Amps

Watts

ON Level

OFF 

Level

FLA

Start

12E-CIM

1/2

115

60

10

18

1100

N/A

N/A

12E-CIA-RF

12” - 15”

6” - 8”

Risk of death, personal injury, or property damage due to explosion, 
fire, or electric shock.

• Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri

-

cally disconnected.

• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of 

power.

• If the disconnect panel is not accessible, contact the electric company to stop service.

Summary of Contents for 12E Series

Page 1: ...comply with national and local electrical and plumbing codes and within Little Giant recommendations may result in electrical shock or fire hazard unsatisfactory performance or equipment failure Know...

Page 2: ...electrical insulation system resulting in electrical shock Risk of bodily injury electric shock or equipment damage This equipment must not be used by children or persons with reduced physical sensor...

Page 3: ...TION Typical Installation 1 Gate Valve 2 Check Valve 3 Union 4 Switch power 5 Pump Power 6 Vent 7 Discharge 8 Gas tight basin 9 Intake 10 Caulking hub 11 3 16 air bleed hole 12 Tethered Float Refer to...

Page 4: ...ge size to reduce pipe friction losses A smaller pipe will restrict capacity and reduce pump performance The pump comes with a 2 NPT female pipe thread discharge Install a union in the discharge line...

Page 5: ...be cooled by pumping fluid The seal may be damaged and the motor may fail if the pump is allowed to run dry Pump should be totally sub merged for proper cooling of the motor when pump is operated for...

Page 6: ...est reservoir 3 Direct the opposite end of the discharge hose back into the basin or test reservoir so that the water discharged from the hose during testing will be contained within the basin or test...

Page 7: ...nents basin pump switch etc for any build up sludge sediment minerals etc that would inhibit functionality of the components If significant remove build up or replace affected components 4 Confirm tha...

Page 8: ...lean air bleed hole Liquid inflow matches pump capacity Larger pump required Defective switch Replace switch Pump runs but does not discharge liquid Check valve installed back wards Check flow indicat...

Page 9: ...eses desde la fecha original de compra por parte del consumidor Para obtener infor maci n completa sobre la garant a consulte www LittleGiant com Especificaciones INSTRUCCIONES SOBRE SEGURIDAD La inst...

Page 10: ...de acortar el cable para que encaje en un panel de control Cualquier empalme entre la bomba y el panel de control debe hacerse dentro de una caja de conexiones montada fuera del dep sito y cumplir co...

Page 11: ...otador adjunto Consulte Especificaciones en la p gina 9 para el nivel ON y el nivel OFF Riesgo de da os a bomba u otros equipos No use esta bomba para bombear agua de mar bebidas cidos soluciones qu m...

Page 12: ...er a de descarga debe tener el mismo di metro que el tama o de descarga para reducir las p rdidas por fricci n de la tuber a Una tuber a m s peque a restringir la capacidad y reducir el rendimiento de...

Page 13: ...su propio circuito sin otras salidas o equipos en la l nea de cir cuito No lo conecte a un ventilador ni a un dispositivo que funcione de manera intermitente Los fusibles y el disyuntor deben tener un...

Page 14: ...o de energ a adecuado que tenga un voltaje congruente con el voltaje de la bomba como se indica en la placa de identificaci n de la bomba 2 Si la l nea de descarga tiene una v lvula de compuerta verif...

Page 15: ...un enchufe de seguridad en el cable de alimentaci n enchufe el cable de ali mentaci n de la bomba a un recept culo con un interruptor de circuito por falla de conexi n a tierra GFCI por si sigla en in...

Page 16: ...y retire dep sitos o residuos Limpiar el impulsor y la voluta 1 Retire los cuatro pernos y cuatro arandelasque fijan la voluta a la carcasa del motor 1 Luego separe la voluta del carcasa del motor IM...

Page 17: ...mprobar que funcione bien Elevaci n demasiado alta para la bomba Revise el desempe o nominal de la bomba Entrada al impulsor obstruido Quite la bomba y l mpiela La bomba est obturada por aire Si est o...

Page 18: ...Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Para la ayuda t cnica por favor p ngase en contacto Form 10000004899 Rev 001 12 20 Copyright 2020 Franklin Electric Co Inc Todos los derec...

Page 19: ...ments ou un joint ayant atteint la fin de sa leur vie utile Ce produit est couvert par une garantie limit e pour une p riode de 36 mois compter de la date d achat originale par le consommateur Pour ob...

Page 20: ...ce soit Il peut uniquement tre rac courci si cela est n cessaire pour le faire rentrer dans le panneau de commande Toute pissure entre la pompe et le panneau de commande doit tre r alis e dans une bo...

Page 21: ...Sp cifications page 19 pour les niveaux sur et arr te Risque de dommages la pompe ou d autres quipements Ne pas utiliser la pompe pour pomper de l eau de mer des boissons de l acide des solutions chi...

Page 22: ...t comporter le moins de coudes pos sible Le tuyau de refoulement doit avoir un diam tre sup rieur ou gal la taille de refoulement de la pompe Un tuyau de diam tre inf rieur limitera les capacit s et r...

Page 23: ...ompe doit tre connect e ou branch e sur son propre circuit sans autre prise ou quipement sur la ligne du circuit Ne le raccordez pas un ventilateur ou tout dispositif fonctionnant par inter mittence L...

Page 24: ...rente avec la tension de la pompe indiqu e sur la plaque signal tique de celle ci 2 Assurez vous que le robinet vanne du conduit de refoulement est ouvert 3 Faites couler de l eau dans le bassin jusqu...

Page 25: ...ai 6 Branchez le cordon d alimentation de la pompe dans un r ceptacle de disjoncteur de fuite de terre GFCI avec une tension compatible avec la tension de la pompe comme indiqu sur la plaque signal ti...

Page 26: ...e l impulseur et de la volute 1 Retirez les quatre boulons et les quatre rondelles qui fixent la volute au bo tier du moteur 1 Puis s parez la volute du bo tier du moteur IMPORTANT Ne pas retirer le c...

Page 27: ...vation est trop lev e pour la pompe V rifiez le tableau des valeurs nominales L aspiration vers l impulseur est obstru e Retirez la pompe et nettoyez la La pompe est bloqu e par de l air Enlever la po...

Page 28: ...Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Droits d auteur 2020 Franklin Electric Co Inc Tous droits r serv s Form 10000004...

Reviews: