Troubleshooting

Creek, Dam, Municipal , Rain Water

The filtration unit when used every day  should be cleaned  and dried daily, 

and s

t

o

r

ed in a cool dry place. It is recommended if the filtration is used on 

a daily basis, to be sanitised once a week. More regular if the water quality is 

poor.

The unit should be disinfected   prior to storage if not being used for more 

than a week.  The unit can be disinfected by pumping disinfection solution 

through the filter and tubing , and having the suction side immersed in 

disinfectant. Take out suction side pump 2 to 3 times to expel excess water ,

replace silicon stoppers and store unit.

Portable filtration unit should  cleaned  sanitised after prolonged 

storage.

Follow the procedure as  above to sanitise the unit using Chlorine 

Dioxide tablets to make up the disinfectant solution.

Hint: Ensure UF cartridge is cleaned on a regular basis, as 

deposits build-up can inhibit flow- to improve taste of the purified

water, the optional activated carbon filtration can be used to 

further improve the water quality.

Making up the Chlorine Dioxide Sanitising solution:  Add one tablet from 

the blister pack ( accessory pack) into 500 ml of water  - allow to dissolve 

for 15 minutes and this will yield a sanitising solution with 100-120 ppm 

free chlorine.

Please report any faults of your unit to our maintenance department, 

for hints on more common problems please refer to the guide below:

Summary of Contents for LUSA1-1C

Page 1: ...re filtration allows for the clarification and disinfection of water in one single step by removing pollen algae bacteria viruses cysts and organic molcules from water The portable filter provides safe potable water from various water sources including dam creek rain water etc Before using the portable water filter please read all the instructions carefully and keep instructions in a safe place ...

Page 2: ... may differ slightly from actual product 4 Pacific Water Technology does not accept any responsibility for failure to observe all the instructions set out in this manual 5 Please store manual in a safe place Please note the icons as listed below Icons have been listed below in accordance with severity of risk Warning failure to comply may lead to personal injury or damage to equipment Attention Re...

Page 3: ...rly stored during trasnportation Please do not attempt to repair unit yourself to prevent any further damage Replace the UF cartridge before blockages prevent further use of unit Store in a cool and dry place to limit the risk of bacterial growth High frequency pumping can cause damage do not exceed 50 strokes min Use dry cotton cloth to keep unit clean do not use acid or alkali solutions Pump cae...

Page 4: ......

Page 5: ...as illustrated above in the schematic Step 3 Step1 Open the carry bag and remove filtration components Step 2 Attach the raw water component tubing and inlet suction strainer to the bottom of the unit as illustrated in schematic 7 The fitting is a push pull connection Operating Instructions Operating Instructions ...

Page 6: ... the outlet tubing Pump as required and dispense water into a receptacle or directly into a water hydration pack Step1 To remove purified water tubing counter rotate swivel connection at filter outlet to unscrew the connection and tubing outlet Step2 The UF cartridge inside the main compartment should be cleaned and can be removed by simply gripping the top of the cartridge and pulling out Flush t...

Page 7: ...from the main body of the filtration unit Invert the filter and try and force out any remaining water Screw cartridge nut clockwise Do not pump when there is no water in the suction side excessive pumping in the absence of water can impact on normal operation Step 5 Insert the two silicon stoppers back into the inlet and outlet connection of the main filtration housing Step 6 Return all components...

Page 8: ...pers and store unit Portable filtration unit should cleaned sanitised after prolonged storage Follow the procedure as above to sanitise the unit using Chlorine Dioxide tablets to make up the disinfectant solution Hint Ensure UF cartridge is cleaned on a regular basis as deposits build up can inhibit flow to improve taste of the purified water the optional activated carbon filtration can be used to...

Page 9: ...Replacement frequency will depend on quality of water source frequency of use and frequency of cleaning of filter Suggested Frequency of filter replacement ...

Reviews: