Lithonia Lighting KBA Installation Instructions Download Page 2

Lithonia Lighting Outdoor

One Lithonia Way,  Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com

  Part  Number: RJ5210035  Rev B

Revision Date: 03/8/10

KB Bollard Series

Installation Instructions

©2001 Acuity Brands Lighting, Inc.
All Rights Reserved. Rev. 02/10

DELIVERY: 

Upon receipt of fixture and accessories (packed separately), thoroughly inspect for any freight damage.  All damage should be reported to the delivery

carrier. Compare the catalog description listed on the packing slip with the fixture label on the inside of the housing to be sure you have received the correct
merchandise.

Troubleshooting:

  If this fixture fails to operate properly, check to make sure:  The proper lamp is installed

correctly.     • The fixture is wired correctly.     • The lamp is not faulty.     • The fixture is grounded correctly.     •
The line voltage at the fixture is correct.    If all these variables have been checked and the fixture still does not
operate as specified, contact your local Lithonia Lighting distributor.

Multi-tap Ballast (TB)

:    The multi-tap ballast will be prewired for 277V at the factory.  This option offers multi

voltage capability.  First determine the correct line voltage.  Then select the corresponding fixture voltage lead,
remove the crimped cap and connect to the supply voltage lead.  The fixture lead marked COM should be
connected to the neutral supply lead for 120 or 277.  For 208 or 240, connect the other incoming hot leg to the
fixture lead marked "COM".  Be sure to cap off all unused fixture leads individually.

Lamp Installation: 

 Prior to installing the lamp in the fixture, check to make sure the lamp is the correct source

and wattage. Screw the lamp securely into the socket, back it out one or two turns, then screw lamp back in,
making sure it is secure. This procedure properly seats lamp in the socket.

TOOLS REQUIRED: 1/8” Allen Wrench, Adjustable Open-end

1.  UNPACK: Leave protective covering on fixture. Lay the fixture on its
side. At the bottom of the fixture, loosen the (4) 3/8" set bolts with a 3/16"
Allen wrench to disengage the cast baseplates.
2.  Make sure conduit does not extend more than 2-1/2" above concrete.
3.  Remove the (4) top nuts and washers from the anchor bolts. Place the
cast baseplate on top of the leveling nuts, with the embossed letters
stated "DOWN" facing toward the  concrete. Place a hand level across
the cast baseplate and level the base by using the leveling nuts.  Check
the level in both directions from 90° from each other, and then reinstall
top washers and nuts on anchor bolts. Before tightening anchor bolt nuts
(for square bollards) make sure baseplate is aligned with curb or walk.
Tighten anchor bolt nuts.
4.  After baseplate is installed, wiring connections can be made. NOTE:
On multiple voltage fixtures, insulate all unused fixture leads individually.
5.  After wiring is done, the bollard should be carefully placed over the
baseplate. Make sure the bollard is properly aligned and seated on the
baseplate.   At this point, the 3/8" set bolts can be tightened. Each set bolt
should be tightened a little at a time. Make one last check to see that the
set bolts are tight and the bollard is plumb, and sides are aligned with
sidewalk or curb (square bollard only).
6.  LENSED BOLLARD ONLY:  Next, loosen the top screw using a 5/32" Allen
wrench. Note the top bolt is captive and does not completely remove. Remove
top cover and any plastic protective covering. Lamp the fixture following lamp
installation instructions. Replace the top cover making sure all interlocking

parts are seated properly before tightening top screw. (It may be easier to fit the lens into the top, and holding them as a unit, set them into place).
7.  LOUVERED BOLLARD ONLY:  Above top louver (recessed under the cap) locate 3-10/24 screws. Use standard 1/8" allen (L-shaped) wrench to loosen. After
all 3 screws are loose (approx 3-4 full turns), rotate cap counter clockwise to lift off and remove. Set cap aside.
8.  Unscrew glass lamp enclosure and remove.
9.  Place correct lamp (wattage and source) into lamp socket and tighten properly. (All fixtures have lamp labels).
10. Reverse step #7.

Top Cover

Captive
Reflector

Lens

Main Housing

Power Module

Cast Baseplate

Anchor Bolts

Follow  the instruction sheets supplied with
the festoon outlet for proper installation.

Screws

Festoon
   Cover

Gasket

Receptacle

Bollard - Square or Round

KBR8-LV

KBD8-LV

KBC8-LV

KBA8-LV

KBS

KBE

KBR

KBD

KBC

KBA