READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

· 

To reduce the risk of death, personal injury or property damage from fi re, electric shock, falling parts, cuts/
abrasions, and other hazards please read all warnings and instructions included with and on the fi xture box and all 
fi xture labels.  

· 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general 
precautions.

· 

Installation and service of luminaires should be performed by a qualifi ed licensed electrician. 

· 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and 
operation and any hazards involved.  Regular fi xture maintenance programs are recommended. 

· 

It will occasionally be necessary to clean the outside of the refractor/lens.  Frequency of cleaning will depend on 
ambient dirt level and minimum light output which is acceptable to user.  Refractor/lens should be washed in a 
solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.  
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing 
damaged gaskets as necessary. 

· 

DO NOT INSTALL DAMAGED PRODUCT!  This luminaire has been properly packed so that no parts should have 
been damaged during transit. Inspect to confi rm.  Any part damaged or broken during or after assembly should be 
replaced.

· 

Recycle: For information on how to recycle LED electronic products, please visit 

www.epa.gov

·

 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible 
contingency to meet in connection with installation, operation, or maintenance.  Should further information be 
desired or should particular problems arise which are not covered suffi ciently for the purchaser’s or owner’s 
purposes, this matter should be referred to Acuity Brands Lighting, Inc. 



Disconnect or turn off power before installation or 
servicing.



Verify that supply voltage is correct by comparing it with 
the luminaire label information.



Make all electrical and grounded connections in 
accordance with the National Electrical Code (NEC) and 
any applicable local code requirements.



All wiring connections should be capped with UL approved 
recognized wire connectors.

WARNING

RISK OF ELECTRIC SHOCK



Allow lamp/fi xture to cool before handling. Do not touch 
enclosure or light source.



Do not exceed maximum wattage marked on luminaire 
label. 



Follow all manufacturer’s warnings, recommendations 
and restrictions for: driver type, burning position, 
mounting locations/methods, replacement and recycling.   

WARNING

RISK OF BURN

CAUTION

RISK OF FIRE



Keep combustible and other materials that can burn, 
away from lamp/lens.  



Do not operate in close proximity to persons, combustible 
materials or substances affected by heat or drying. 

CAUTION

RISK OF INJURY



Wear gloves and safety glasses at all times when removing 
luminaire from carton, installing, servicing or performing 
maintenance.



Avoid direct eye exposure to the light source while it is on.

Summary of Contents for DSX0

Page 1: ...laced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for t...

Page 2: ...se ESD shorten lamp life or alter performance Some components inside the fixture may not be serviceable In the unlikely event your unit may require service stop using the unit immediately and contact an ABL representa ve for assistance Always read the fixtures complete installa on instruc ons prior to installa on for any addi onal fixture specific warnings CAUTION RISK OF PRODUCT DAMAGE Please see...

Page 3: ...n the block making certain the wires are not pinched For ease of installation the mounting block will hold the weight of the luminaire prior to tightening the mounting bolt See Figure 2 3 To secure the fixture open doorframe by loosening the 2 captive screws using 3 16 allen wrench See Figure 3 4 Tighten the locking hex head bolt inside the arm with a 9 16 socket to 20 30 ft lbs torque overtighten...

Page 4: ...ert and tighten 4 3 8 diameter by 1 1 4 stainless steel hex head screws into the threaded opening of the cover plate by turning approximately 6 7 full turns see diagram above 6 To prepare fixture for installation open doorframe by loosening the 2 captive screws using 3 16 allen wrench See Figure 3 7 Pull the wires from the fixture through the mounting block on the cover plate Place fixture onto th...

Reviews: