Litex WH44OSB5C1S Installation Manual Download Page 9

10. Testing Your Fan.

It is recommended that you test fan before 
finalizing installation. Restore power from circuit 
box and light switch (if applicable). Test fan 
speeds with the pull chain on switch housing 
located to the RIGHT of the reverse switch 
(labeled FAN). Start at the OFF position (no blade 
movement). First pull will set the fan to HI. 
Second pull will set the fan to MEDIUM. Third pull 
will set the fan to LOW. Fourth pull will again set 
the fan to OFF setting. If applicable, test light with 
pull chain on switch housing located to the LEFT 
of the reverse switch (labeled LIGHT). (

diagram 1

If fan and/or light do/does not function, please 
refer to "Troubleshooting" section to solve any 
issues before contacting Customer Service.

Turn fan completely off 

before 

moving the 

reverse switch. Set reverse switch to recirculate 
air depending on the season:
 

- DOWN position in summer (

diagram 2

)

 

- UP position in winter (

diagram 3

)

A ceiling fan will allow you to raise your 
thermostat setting in summer and lower your 
thermostat setting in winter without feeling a 
difference in your comfort.

Important:

 Reverse switch must be set either 

completely UP

 or 

completely DOWN

 for fan to 

function. If the reverse switch is set in the 

middle

 

position (

diagram 4

), fan will not operate.

Attach pull chain extension(s) supplied or custom 
pull chain extension(s) (sold separately) to end(s) 
of the pull chain(s).

page 8

diagram 2

diagram 3

diagram 4

diagram 1

fan pull chain
extension

light pull

chain extension

motor housing

reverse
switch

Summary of Contents for WH44OSB5C1S

Page 1: ...ssembly pg 5 Motor Housing Assembly pg 5 Blade Assembly pg 6 Light Kit Assembly Optional pgs 6 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 16 53...

Page 2: ...n If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Ele...

Page 3: ...ed for repairs Check against parts inventory that all parts have been included 2 Parts Inventory a hanging bracket 1 piece b motor housing 1 piece c motor assembly 1 piece d blade arm 5 pieces e blade...

Page 4: ...is suitable for room sizes up to 144 square feet 13 4 square meters Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WA...

Page 5: ...cal Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those referred to below please use a qualified electrician When fan is secured in place o...

Page 6: ...in motor housing to align with loosened screws in hanging bracket Twist motor housing to lock Re insert the 2 screws that were previously removed and then tighten all screws to secure motor housing m...

Page 7: ...lide 3C Clips completely under blade screw posts so edges of blade screw posts are captured by the recessed groove on the 3C Clips Remove blade arm screws lock washers from underside of motor If plast...

Page 8: ...gap on top edge of the switch housing cap with the reverse switch on switch housing for the correct fit Re insert 3 screws that were previously removed and use a Phillips screwdriver to secure all sc...

Page 9: ...bleshooting section to solve any issues before contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN p...

Page 10: ...0 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX...

Reviews: