6. Wiring.

Find a secure attachment point(wood ceiling 
joist) and secure safety cable. Use a heavy duty 
wood screw(not supplied), washer and lock 
washer (not supplied) over safety cable loop. 

Important

Be sure outlet box is properly grounded 

or that a ground (GREEN or Bare) wire is present.

Make the following electrical connections.
Connect 

BLACK

 wire from fan to 

BLACK

 wire 

from ceiling. Connect 

WHITE

 wire from fan to 

WHITE

 wire from ceiling. Connect 

GREEN 

wire 

from

 

fan to 

BARE/GREEN

 wire from ceiling.

* Wrap all wire nuts with electrical tape as an 
extra measure for safety.  Gently push taped wire 
nuts into junction box.

wall control

back plate

back plate screw

back plate screw

safety cable

wood screw
& washer

hanging bar

wood joist

black

white

black

green/ground

bare/ground

from fan

white

*

7. Wiring - Wall Control

Remove existing wall switch. Remove wall 
control back plate by unscrewing two screws on 
top and bottom of the wall control. Secure 
control back plate to wall or structure with 
screws from existing wall switch.

Make the following electrical connections.
Connect 

BLACK

 wire from wall control to 

BLACK 

(AC  TO FAN) 

wire from wall. Connect 

BLACK 

wire from

 

wall control to 

BLACK (AC IN)

 wire 

from wall. 

* Wrap all wire nuts with electrical tape as an 
extra measure for safety.  Gently push taped wire 
nuts into back plate.

Attach wall control to back plate using 
previously removed screws.

black

black

AC IN

black

AC IN

black

TO FAN

black 

TO FAN

black

*

wall control

wire

from 

ceiling

Summary of Contents for UT56 3M Series

Page 1: ...xx3M Table of Contents Safety Tips pg 1 Unpacking your fan pg 2 Installation preparation pg 3 Fan Assembly pg 4 Wiring pg 5 Canopy Assembly pg 6 Light Kit Assembly pg 7 Test Fan pg 7 Troubleshooting p...

Page 2: ...re is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire nuts wire connectors to use 5 Electrical diagrams are for reference only Light kits...

Page 3: ...r Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included a j...

Page 4: ...perating light switch is turned to the off position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing...

Page 5: ...the wiring connections as shown in steps 6 NOTE The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations that may occur I...

Page 6: ...plate back plate screw back plate screw safety cable wood screw washer hanging bar wood joist black white black green ground bare ground from fan white 7 Wiring Wall Control Remove existing wall switc...

Page 7: ...lower washer and rubber cushion intact Lower blade over rubber cushion and attach with previously removed screw and washer Tighten securely Repeat with the remaining blades Lift canopy over hanging b...

Page 8: ...ETURN FAN MOTOR ONLY shipping prepaid to Litex Industries We will repair or ship purchaser a replacement motor and Litex will pay the return shipping cost 6 YEAR LIFETIME WARRANTY LITEX INDUSTRIES INC...

Reviews: