SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box 

or circuit panel before you begin the fan installation or before servicing the fan or installing accessories.

1.         Read all instructions and safety information carefully before installing your fan and save these 

instructions.

2.         Make sure all electrical connections comply with Local Codes or Ordinances and the National 

Electrical Code.  If you are unfamiliar with electrical wiring or if the house/building wires are 
different colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to 

rotate, and at least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade 
tips.  The fan should be mounted at least thirty (30) inches (76 centimeters) from walls or other 
upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of 

supporting at least 35 pounds (16 kilograms).  The box must be supported directly by the 
building structure.  Use only UL listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box 

marked "Acceptable for Fan Support,"  and use the mounting screws provided with the outlet box.  
Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan 
support and may need to be replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with 

this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan. If your 
house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead 
wires, consult an electrician for the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be UL 

listed and marked suitable for use with the model fan you are installing.  Switches must be UL 
general use switches.  Refer to the instructions packaged with the light kits and switches for 
proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed 

carefully up into the outlet box.  The wires should be spread apart with the grounded 
conductor and the equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of electrical shock and fire, do not use this fan with any variable (rheostat) 

wall control. (

Note

: This fan 

is

 suitable for use with remote control devices.)

8.        Do not operate the reverse switch until the fan has come to a complete stop.
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after 

installation.  Do not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working 

around or cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly 

dampened cloth will be suitable for most cleaning.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to 

cover all possible conditions and situations that may occur.  It must be understood that common sense 
and caution are necessary factors in the installation and operation of this fan.

Summary of Contents for PZ52ABZ5C

Page 1: ...nstallation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Light Kit Assembly Optional pgs 7 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 26 46 lb 12 kg E192641 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA For Models PZ52ABZ5C PZ52BNK5C ...

Page 2: ...wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switche...

Page 3: ...l plate pre attached to light kit fitter 1 piece l finial pre attached to light kit fitter 1 piece m hardware packs page 2 g Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that ...

Page 4: ...and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the box is securely attached to the building structure and can support the full weight of the fan Ensure it is clearly marked Suitable for Fan Support If not it must b...

Page 5: ... and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely Slide downrod through canopy and yoke cover Thread electrical wires through downrod and pull extra wire slack from the upper end of the downrod Tip Apply small piece of electrical tape to the ends of the electrical wires to keep them together when threading them through the downr...

Page 6: ...ical connections comply with Local Codes or Ordinances and the National Electrical Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those referred to below please use a qualified electrician When fan is secured in place on the hanging bracket electrical wiring can be made diagram 1 as follows Connect BLACK and BLUE wire from fan to BLACK wi...

Page 7: ...side Then if applicable remove plastic motor locks and discard Align blade arm holes with motor screw holes and attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat this procedure with remaining blade arms Secure all screws blade arm screws lock washers motor housing blade arm blade blade attachment screws and washers canopy hanging bracket screw If nec...

Page 8: ... touching Remove finial finial plate and threaded washer from threaded rod at bottom of light kit fitter Raise glass shade in order to guide pull chains through corresponding holes at the bottom of the glass shade Align threaded rod with hole in middle of glass shade and push up gently until threaded rod comes through hole Be sure pull chain for fan operation does not rub against bulbs during oper...

Page 9: ...pending on the season Attach pull chain extension s supplied to pull chain s or use custom pull chain extension s sold separately 9 Light Kit Assembly Optional cont If you wish to use fan WITHOUT the light kit remove hex nut and lock washer from threaded rod at top of light kit fitter Remove switch housing cap Locate small plastic cap in hardware pack and insert firmly into hole in middle of switc...

Page 10: ...TD will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTRIES LTD will repair or replace at no charge to th...